Grace Industries SuperCELL SC500-LW-GPS User Information Download Page 5

Grace Industries, Inc.

5

CANNOT

 monitor or send Alarm, Page, Par, or Roll Call 

messages, nor will these messages be logged in the 
SuperCELL® device’s Event Counter. Any Alarm, Page, Par, 
or Roll Call messages received, while in IrDA Transfer Mode, 
will be subject to the SuperCELL® device’s inhibit timer.

Interrupting an IrDA transfer while in progress may corrupt 

the SuperCELL® device’s name database. If this should occur, 
the SuperCELL® name database will need to be reloaded.  

Pressing the MENU/PWR button navigates away from the 

IrDA Transfer page. Resetting the device exits out of IrDA 
Transfer Mode and returns the SuperCELL® to the home page. 

Setup Mode Page 4 - View Adjust 

The View Adjust page allows the display contrast to be 

adjusted for easier viewing of the SuperCELL® device’s 
display

. Adjusting the display contrast may be necessary if 

the SuperCELL® is used in extreme temperatures. 

To adjust the display contrast

, navigate to the View 

Adjust page by pressing the MENU/PWR button. At the View 
Adjust page, press the UP and DWN buttons to increase 
(or decrease) the display contrast by 1, and the * and # to 
increase (or decrease) the display contrast by 10. 

Pressing MENU/PWR will navigate away from the View 

Adjust page. Resetting the device will exit out of Setup Mode 
and return the SuperCELL® to the home page. 

Setup Mode Page 5 - Enable GPS 

Use the SEL/PWR button to enable or disable the GPS. 

End of Setup Mode Screens

Safety Certifi cations

Intrinsically Safe, Sécurité Intrinsèque

SuperCell

®

 SC500 Models Intrinsically Safe per ANSI/UL913 For use 

in Class 1, Groups A, B, C and D; Class II, Groups E, F, G; Div. 1 Haz-
ardous Locations. CSA C22.2 No.157. 

Temperature Code T6. IP67. Exia Rated 4.2VDC.

Radio Certifi cations

• 

FCC ID:  J5XT3HEP

• 

IC:  5916A-T3HEP

• 

Australia / New Zealand: Compliant to ACMA AS/NZS 
CISPR22:2006, Class A Digital Apparatus | AS/NZS 4268:2012 for 
Intentional Radiators

• 

EMC93142C-ACMA

• 

EMC93142C-AS/NZS 4268

WARNINGS, AVERTISSEMENTS 

WARNING!

 To prevent ignition of hazardous atmosphere, battery 

must only be charged in area known to be nonhazardous. 

AVERTISSEMENT!

 Pour éviter l’infl ammation d’une atmosphère 

dangereuse, les batterie doivent être chargées seulement dans 
une zone connu comme être non dangereuse.

FCC Statements

Changes or modifi cations not expressly approved by the party re-
sponsible for compliance could void the user’s authority to oper-
ate the equipment. 

NOTE: This equipment has been tested and found to comply with 
the limits for a Class A digital device, pursuant to part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in 
a commercial environment. This equipment generates, uses, and 
can radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harmful in-
terference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own 
expense.

Industry Canada Statements

This Class A digital apparatus complies with Canadian ICES-003.

This device complies with Industry Canada licence-exempt RSS 
standard(s). Operation is subject to the following two conditions: 
(1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause un-
desired operation of the device.

Cet appareil numérique de la classe A est conforme à  la norme 
NMB-003 du Canada.(select the class for your device)

Le présent appareil est conforme aux CNR d’Industrie Canada ap-
plicables aux appareils radio exempts de licence. L’exploitation est 
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas 
produire de brouillage, et (2) l’utilisateur de l’appareil doit accept-
er tout brouillage radioélectrique subi, même si le brouillage est 
susceptible d’en compromettre le fonctionnement.

Summary of Contents for SuperCELL SC500-LW-GPS

Page 1: ...afety monitoring feature which provides the LoneWorker with motion sensing protection Alarm Acknowledgment When a SuperCELL is in an alarm condition an Alarm Acknowledgment message can be sent from an...

Page 2: ...rm has been cleared or reset To force Super CELL to turn off even with an active alarm hold down the Up button along with both side PWR buttons SuperCELL Display Icons Quick Start Guide Always test Su...

Page 3: ...tons to cycle through four Latitude Longitude display formats Degrees LAT 41 313266 N LON 80 339424 W Degrees Minutes DD mm mmmm LAT 41 18 7969 N LON 80 20 3736 W Degrees Minutes Seconds DD mm ss ss L...

Page 4: ...n the SuperCELL to the home page Setup Mode Page 1 Alarm Disabled Notification Setup Mode Page 2 Firmware Versions Setup Mode Page 3 IrDA Transfer Mode Setup Mode Page 4 View Adjust Setup Mode Page 5...

Page 5: ...l Radiators EMC93142C ACMA EMC93142C AS NZS 4268 WARNINGS AVERTISSEMENTS WARNING To prevent ignition of hazardous atmosphere battery must only be charged in area known to be nonhazardous AVERTISSEMENT...

Page 6: ...counts down to zero Monitoring Authority The Monitoring Authority is the person people responsible for monitoring the status of the telemetry devices used by the various on scene personnel usually fro...

Page 7: ...or customer is responsible for return shipping freight charges The sole and exclusive remedy under all guarantees or warranties express or implied is strictly limited to repair or replacement as here...

Page 8: ...305 Bend Hill Road Fredonia PA 16124 USA www graceindustries com 724 962 9231...

Reviews: