Grace Industries, Inc.
5
CANNOT
monitor or send Alarm, Page, Par, or Roll Call
messages, nor will these messages be logged in the
SuperCELL® device’s Event Counter. Any Alarm, Page, Par,
or Roll Call messages received, while in IrDA Transfer Mode,
will be subject to the SuperCELL® device’s inhibit timer.
Interrupting an IrDA transfer while in progress may corrupt
the SuperCELL® device’s name database. If this should occur,
the SuperCELL® name database will need to be reloaded.
Pressing the MENU/PWR button navigates away from the
IrDA Transfer page. Resetting the device exits out of IrDA
Transfer Mode and returns the SuperCELL® to the home page.
Setup Mode Page 4 - View Adjust
The View Adjust page allows the display contrast to be
adjusted for easier viewing of the SuperCELL® device’s
display
. Adjusting the display contrast may be necessary if
the SuperCELL® is used in extreme temperatures.
To adjust the display contrast
, navigate to the View
Adjust page by pressing the MENU/PWR button. At the View
Adjust page, press the UP and DWN buttons to increase
(or decrease) the display contrast by 1, and the * and # to
increase (or decrease) the display contrast by 10.
Pressing MENU/PWR will navigate away from the View
Adjust page. Resetting the device will exit out of Setup Mode
and return the SuperCELL® to the home page.
Setup Mode Page 5 - Enable GPS
Use the SEL/PWR button to enable or disable the GPS.
End of Setup Mode Screens
Safety Certifi cations
Intrinsically Safe, Sécurité Intrinsèque
SuperCell
®
SC500 Models Intrinsically Safe per ANSI/UL913 For use
in Class 1, Groups A, B, C and D; Class II, Groups E, F, G; Div. 1 Haz-
ardous Locations. CSA C22.2 No.157.
Temperature Code T6. IP67. Exia Rated 4.2VDC.
Radio Certifi cations
•
FCC ID: J5XT3HEP
•
IC: 5916A-T3HEP
•
Australia / New Zealand: Compliant to ACMA AS/NZS
CISPR22:2006, Class A Digital Apparatus | AS/NZS 4268:2012 for
Intentional Radiators
•
EMC93142C-ACMA
•
EMC93142C-AS/NZS 4268
WARNINGS, AVERTISSEMENTS
WARNING!
To prevent ignition of hazardous atmosphere, battery
must only be charged in area known to be nonhazardous.
AVERTISSEMENT!
Pour éviter l’infl ammation d’une atmosphère
dangereuse, les batterie doivent être chargées seulement dans
une zone connu comme être non dangereuse.
FCC Statements
Changes or modifi cations not expressly approved by the party re-
sponsible for compliance could void the user’s authority to oper-
ate the equipment.
NOTE: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful in-
terference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
Industry Canada Statements
This Class A digital apparatus complies with Canadian ICES-003.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause un-
desired operation of the device.
Cet appareil numérique de la classe A est conforme à la norme
NMB-003 du Canada.(select the class for your device)
Le présent appareil est conforme aux CNR d’Industrie Canada ap-
plicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas
produire de brouillage, et (2) l’utilisateur de l’appareil doit accept-
er tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.