TURN ON:

 Remove SuperCELL® from the Charging Base. 

TURN OFF:

 Insert SuperCELL® into the Charging Base. 

PAGE NAVIGATION:

 Pressing the MENU/PWR button cycles 

through the pages on the SuperCELL®. 

MOTION ALARM:

 If SuperCELL® remains motionless for the 

preset length of time, the SuperCELL® will sound a repeating 
alarm tone and transmit man-down alarm messages. To clear 
Alarm and reset the SuperCELL®, simultaneously press the 
MENU/PWR and SEL/PWR buttons. 

Motion Alarm cannot be 

disabled or adjusted by the user. Time to Alarm for SC500-
LW is set to 120 seconds unless other timing is specifi ed. 
Pre-Alert occurs after approximately 108 seconds of no 
motion detected. 

PANIC ALARM:

 Activate the Emergency Alarm by pressing 

the top button. A Panic Alarm signal will be sent and ALARM 
will be displayed. To clear Alarm and reset the SuperCELL®, 
simultaneously press the MENU/PWR and SEL/PWR buttons. 

EVACUATION ACKNOWLEDGMENT:

 If an Evacuate message 

is received by the SuperCELL®, it can be manually acknowl-
edged by simultaneously pressing the MENU/PWR and SEL/
PWR buttons. 

ALARM MONITORING:

 Alerts the Lone Worker that a GRACE 

Man-Down telemetry device, within signaling range, is 

 

transmitting an alarm message. This alert can be cleared 
from SuperCELL® by  simultaneously press the MENU/PWR 
and SEL/PWR buttons.

NOTE:

 If an alarm has been received, SuperCELL® will not turn 

off  until the alarm has been cleared or reset. To force Super-
CELL® to turn off  (even with an active alarm) hold down the 

Up

 

button along with both side 

PWR

 buttons. 

SuperCELL® Display Icons

Quick-Start Guide

Always test SuperCELL® prior to use

Low Battery Indication / Battery Charging

When approximately 3 hours of operating time remain 

in standby mode, the SuperCELL® will display a plug icon 
on the display status screen. The power-on tones are not 
emitted when SuperCELL® has a low battery. Low battery is 
also indicated by the Operational Status LED changing to a 
periodic Red strobe. A double chirp sounds once every fi ve 
minutes with audio enabled. 

Warning: There are no audible 

low battery sounds with audio tones disabled.

When low battery is indicated, less than 3 hours of 

operating time remain and the battery should be charged 
immediately. 

With the charger provided, recharge time is approximately 

6 hours from a low battery warning and 9 hours for a dead 
battery. Due to current limits imposed by Intrinsic Safety 
requirements, a unit that has gone completely dead will 
have to be removed from the charging base and reinserted 
when the charging light turns Red. Typical operation time 
between recharging is approximately 24 hours in standby/
ready mode. 

Plug the charger into an outlet. It takes approximately 20 

seconds for the Green charger LED to light up. If it does not 
turn on or a Red LED turns on, then the battery is either too 
hot or cold, or has a fault. 

Charging is complete when the Green charge LED starts to 

slowly fl ash. 

120VAC Adapter

Optional 12VDC Adapter

Green 

Charge 

LED

Charging Base

Summary of Contents for SuperCELL SC500-LW-GPS

Page 1: ...afety monitoring feature which provides the LoneWorker with motion sensing protection Alarm Acknowledgment When a SuperCELL is in an alarm condition an Alarm Acknowledgment message can be sent from an...

Page 2: ...rm has been cleared or reset To force Super CELL to turn off even with an active alarm hold down the Up button along with both side PWR buttons SuperCELL Display Icons Quick Start Guide Always test Su...

Page 3: ...tons to cycle through four Latitude Longitude display formats Degrees LAT 41 313266 N LON 80 339424 W Degrees Minutes DD mm mmmm LAT 41 18 7969 N LON 80 20 3736 W Degrees Minutes Seconds DD mm ss ss L...

Page 4: ...n the SuperCELL to the home page Setup Mode Page 1 Alarm Disabled Notification Setup Mode Page 2 Firmware Versions Setup Mode Page 3 IrDA Transfer Mode Setup Mode Page 4 View Adjust Setup Mode Page 5...

Page 5: ...l Radiators EMC93142C ACMA EMC93142C AS NZS 4268 WARNINGS AVERTISSEMENTS WARNING To prevent ignition of hazardous atmosphere battery must only be charged in area known to be nonhazardous AVERTISSEMENT...

Page 6: ...counts down to zero Monitoring Authority The Monitoring Authority is the person people responsible for monitoring the status of the telemetry devices used by the various on scene personnel usually fro...

Page 7: ...or customer is responsible for return shipping freight charges The sole and exclusive remedy under all guarantees or warranties express or implied is strictly limited to repair or replacement as here...

Page 8: ...305 Bend Hill Road Fredonia PA 16124 USA www graceindustries com 724 962 9231...

Reviews: