Grace Industries, Inc.
2
TURN ON:
Remove SuperCELL® from the Charging Base.
TURN OFF:
Insert SuperCELL® into the Charging Base.
PAGE NAVIGATION:
Pressing the MENU/PWR button cycles
through the pages on the SuperCELL®.
MOTION ALARM:
If SuperCELL® remains motionless for the
preset length of time, the SuperCELL® will sound a repeating
alarm tone and transmit man-down alarm messages. To clear
Alarm and reset the SuperCELL®, simultaneously press the
MENU/PWR and SEL/PWR buttons.
Motion Alarm cannot be
disabled or adjusted by the user. Time to Alarm for SC500-
LW is set to 120 seconds unless other timing is specifi ed.
Pre-Alert occurs after approximately 108 seconds of no
motion detected.
PANIC ALARM:
Activate the Emergency Alarm by pressing
the top button. A Panic Alarm signal will be sent and ALARM
will be displayed. To clear Alarm and reset the SuperCELL®,
simultaneously press the MENU/PWR and SEL/PWR buttons.
EVACUATION ACKNOWLEDGMENT:
If an Evacuate message
is received by the SuperCELL®, it can be manually acknowl-
edged by simultaneously pressing the MENU/PWR and SEL/
PWR buttons.
ALARM MONITORING:
Alerts the Lone Worker that a GRACE
Man-Down telemetry device, within signaling range, is
transmitting an alarm message. This alert can be cleared
from SuperCELL® by simultaneously press the MENU/PWR
and SEL/PWR buttons.
NOTE:
If an alarm has been received, SuperCELL® will not turn
off until the alarm has been cleared or reset. To force Super-
CELL® to turn off (even with an active alarm) hold down the
Up
button along with both side
PWR
buttons.
SuperCELL® Display Icons
Quick-Start Guide
Always test SuperCELL® prior to use
Low Battery Indication / Battery Charging
When approximately 3 hours of operating time remain
in standby mode, the SuperCELL® will display a plug icon
on the display status screen. The power-on tones are not
emitted when SuperCELL® has a low battery. Low battery is
also indicated by the Operational Status LED changing to a
periodic Red strobe. A double chirp sounds once every fi ve
minutes with audio enabled.
Warning: There are no audible
low battery sounds with audio tones disabled.
When low battery is indicated, less than 3 hours of
operating time remain and the battery should be charged
immediately.
With the charger provided, recharge time is approximately
6 hours from a low battery warning and 9 hours for a dead
battery. Due to current limits imposed by Intrinsic Safety
requirements, a unit that has gone completely dead will
have to be removed from the charging base and reinserted
when the charging light turns Red. Typical operation time
between recharging is approximately 24 hours in standby/
ready mode.
Plug the charger into an outlet. It takes approximately 20
seconds for the Green charger LED to light up. If it does not
turn on or a Red LED turns on, then the battery is either too
hot or cold, or has a fault.
Charging is complete when the Green charge LED starts to
slowly fl ash.
120VAC Adapter
Optional 12VDC Adapter
Green
Charge
LED
Charging Base