Grace Industries HIDPass5Config User Information Download Page 5

Page 5

S5T5DLC-1 UI 1119

10. Once download is complete, your log will be displayed in a table as shown below. The events will be 

indexed from #1 (as the most recent) to the oldest event. 

A.  Each event will have a timestamp of when the event occurred. 

1.  Note: the unit has an internal clock which is used to track time and log events, this is set from 

the factory but runs off of the PASS units batteries. If the PASS’s batteries go dead or are 
removed for more than 30 Minutes, the clock will lose its time reference and revert back to a 
default time of 04/05/2063). 

2.  If using Grace Watch/In Command software with TPASS

®

5 or upgraded SuperPASS

®

5X, you 

can confi gure it to sync/update the clock automatically while connected to Grace Watch/In 
Command. If not using Grace Watch/In Command for this command, then the PASS unit’s 
Clock must be manually set as instructed in 

Appendix B Setting the Clock.

11. The Event column displays a text based description of the logged event and color codes it based on 

its event type. See 

Appendix A

 for list of common events and their description. 

A. Red:  Alarms. 

B.  Yellow:  Warnings. 

C.  Blue:  System info (clock and setup data). 

D.  White, Purple, and others:  Additional system data. 

Summary of Contents for HIDPass5Config

Page 1: ...use with SP5 SP5X TP5 and TP5 GPS Models HIDPass5ConfigUSBCable S5T5DLC 1 isusedtodownloadinternaldatalogs setclock set AlarmDelay anddeviceupgradeofSuperPASS 5andTPASS 5 Mustbeusedwithappropriate so...

Page 2: ...a download link 2 Now that you have the installer Run HIDPass5Config Installer HIDPass5Config x xx Setup exe x xx represents the version of the HIDPass5Config tool Be sure to have the latest version...

Page 3: ...lign with the Key Slot 3 Remove Accountability Key to power unit ON 4 After the power up tones an escalating serious of audio tones connect USB cable to PC computer 5 Wait for the PASS to go through c...

Page 4: ...nd please recheck connections and verify all four front Green LED s are on If still not showing Status Device Found disconnect and retry from Step 2 Connect USB Cable 8 To get logs from device click t...

Page 5: ...me reference and revert back to a default time of 04 05 2063 2 If using Grace Watch In Command software with TPASS 5 or upgraded SuperPASS 5X you can configure it to sync update the clock automaticall...

Page 6: ...ge was received 14 Evac Roll Call PAR Check Manual Acknowledge Side buttons pressed to acknowledge the indicated message s 15 Battery Low The internal Low Battery detection threshold has been exceeded...

Page 7: ...nter a Custom Time and then press the Set Clock Button Pass will produce a tone to denote it received the message and set the clock 3 Alarm Delay time is the delay on how long alarm button must be hel...

Page 8: ...not have a SuperPASS 5X connected See the red arrow pointing to device type below Before you can upgrade your device you must contact your Grace Industries sales representative to obtain a Grace Conv...