IMPORTANT  NOTICE

Use TM Series meters with water and other 

chemicals compatible with wetted compo-

nents. Do not use to meter fuel or incompatible 

chemicals. TM Series meters are available with 

either a computer for local electronic display, or 

a conditioned signal output module to provide a 

digital signal to customer interfacing equipment. 

TM Series meters with computer display mea-

sure in gallons or litres. Refer to the Calibration 

Section for details.

TM Series Electronic Water Meters

User Manual

Rev. B   920786-02

04/13

TABLE  OF  CONTENTS

English ...........................................................1
Español ..........................................................8
Deutsch .......................................................15
Italiano .........................................................22
Français .......................................................29

SAVE THESE INSTRUCTIONS

These meters are not legal for trade applications.
TM Series meters are very sensitive to electric 

noise if operated within 1 to 2 inches of some 

electric motors or other sources of electronic 

noise.

INSTALLATION

Connections

Install your meter in-line either horizontally or 

vertically or at the end of the hose adjacent to 

the nozzle. Installation to metal connections is 

not recommended. Install as follows:
1.  Plan to install turbine with a minimum straight 

pipe length as follows:
•  Upstream from the turbine, allow a mini-

mum straight pipe length of 10 times the 

internal diameter of the turbine.

• Downstream from the turbine, allow a 

minimum straight pipe length of 5 times 

the internal diameter of the turbine.

2.  For Spigot (Pipe) End use only primer and 

solvents approved for  PVC gluing.

 

For NPT and BSP Fittings wrap all connec-

tions with 3 to 4 wraps of thread tape (optional 

to use pipe thread sealant). Make sure the 

tape does not intrude into the flow path.

TM Meter with Computer Display

TM Digital Pulse Meter

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for TM050

Page 1: ...inches of some electric motors or other sources of electronic noise INSTALLATION Connections Install your meter in line either horizontally or vertically or at the end of the hose adjacent to the nozz...

Page 2: ...curls can adversely affect accu racy Correct the problem prior to turbine installation NOTE Do not over tighten the flange bolts This may cause the gasket to be compressed into the flow stream and ma...

Page 3: ...ule and lift the module from the turbine 2 To change terminal block connections loosen the appropriate screws Reconnect the wires in the proper positions andtighten the screws 3 Install the batteries...

Page 4: ...eplaceable batteries When display becomes dim faded or the low battery message appears see below the batteries need to be replaced Reference the Maintenance Section for details Factory and Field Calib...

Page 5: ...ct When satisfied with the value press both CALIBRATE and DIS PLAY buttons simultaneously CALEnd will be displayed and unit will go back to normal operation less the FAC factory calibration icon 4 All...

Page 6: ...becomes dim blank or the low battery message appears see below replace the batteries as follows 1 Remove the four Phillips head screws from the face of the meter and lift the faceplate from the turbin...

Page 7: ...ch 222 kg 381 kg 381 kg 1 inch 299 kg 626 kg 666 kg 2 inch 354 kg 807 kg 875 kg Dimensions cm W x H x L Without Fitting With NPT Fitting 5 3 x 6 4 x 10 9 5 3 x 6 9 x 15 2 5 3 x 6 9 x 11 2 5 3 x 7 3 x...

Reviews: