P O W E R
Connect battery (included) red wire (+) to
terminal.
Connect battery (included) black wire (–) to any
COM
terminal.
9V Battery (included)
S I G N A L I N P U T
Connect either coil wire to
COIL_A
terminal.
Connect other coil wire to
COIL_B
terminal.
Connect shield cable, if any, to any
COM
terminal.
NOTE: Leave meter side of shield wire unconnected.
Sine Wave (coil)
continued on next page
4
OUTPUT
P
.U.R.
OUTPUT
P
.U.R.
Connect either wire to
LO-F_IN
terminal.
Connect other wire to any
COM
terminal.
Contact Closure (reed switch)
OUTPUT
P
.U.R.
GM
METER
Connect signal wire to
HI-F_IN
terminal.
Connect ground wire to any
COM
terminal.
Square Wave (active drive)
OUTPUT
P
.U.R.
G SERIES
OR
G2
METERS
Connect power wire (7-30 VDC) to
EXT_V(+)
terminal.
Connect ground wire to any
COM
terminal.
External Power
OUTPUT
P
.U.R.
Optional to connect
to HI-F_IN.