SPECIFICATIONS – LOCAL MODEL
Materials:
Acetal, Amorphous Nylon, PET Polyester, Polyester (de-
cals), Viton (gasket & seals), Stainless Steel (fasteners)
Power Source:
Battery (9V): 6.5V to 20V acceptable range.
Quiescent current (over and above current drawn by
display module) at the battery input is typically less
than 15uA.
External Power: 7V to 30V acceptable range. Quiescent
current (over and above current drawn by display
module) at the external power input is typically less than
90uA.
Battery Life:
1,800 hours
Configuration:
2-Totals (1 cumulative and 1 batch), Rate, 2 Cals
(Factory calibration in gallons or litres; 2 field calibrations)
Input Signal:
Hall Effect, Reed Switch, NPN, Open Collector or
Sine Wave
Time Base:
Hours or minutes
Unit of Measure:
U.S. gallons or litres
Accuracy:
No additional error over coupled flow meter’s accuracy
Frequency Range:
0 to 1,000 hertz
Batch Total:
Up to 999,999
Cumulative Total:
Up to 999,999
Temperature:
+14°F to +140°F (–10°C to +60°C)
Cable:
N/A
Mechanical Connections:
Display is mounted directly to flow meter body
Electrical Connections:
GG500 - One strain relief port: one threaded plug
GG510 - Two threaded plugs
G2 Series - One strain relief port: one threaded plug
GM Local Models - One strain relief port: one threaded
plug (GM001, GM002 & GM003)
GM 1/2 in. and Larger - Two threaded plugs (GM005 -
GM020)
Shipping Weight:
1 lb. (.45 kg)
SPECIFICATIONS – REMOTE MODEL
Materials:
Acetal, Amorphous Nylon, PET Polyester, Polyester (de-
cals), Viton (gasket & seals), Stainless Steel (fasteners),
PVC (cable jacket)
Power Source:
Battery (9V): 6.5V to 20V acceptable range.
Quiescent current (over and above current drawn by
display module) at the battery input is typically less
than 15uA.
External Power: 7V to 30V acceptable range. Quiescent
current (over and above current drawn by display
module) at the external power input is typically less than
90uA.
Battery Life:
1,800 hours
Configuration:
2-Totals (1 cumulative and 1 batch), Rate, 2 Cals
(Factory calibration in gallons or litres; 2 field calibrations)
Input Signal:
Hall Effect, Reed Switch, NPN, Open Collector or
Sine Wave
Time Base:
Hours or minutes
Unit of Measure:
U.S. gallons or litres
Accuracy:
No additional error over coupled flow meter’s accuracy
Frequency Range:
0 to 1,000 hertz
Batch Total:
Up to 999,999
Cumulative Total:
Up to 999,999
Temperature:
+14°F to +140°F (–10°C to +60°C)
Cable:
20 feet, 3-conductor (red, black & white), tinned drain
wire, 22 AWG, PVC jacket .212 dia., (Reference Belden
9363 or equivalent cable)
Mechanical Connections:
Wall or pipe mountable with standard U-bolts
Electrical Connections:
GG500 - One strain relief port: one threaded plug
GG510 - Two threaded plugs
G2 Series - One strain relief port: one threaded plug
GM Local Models - One strain relief port: one threaded
plug (GM001, GM002 & GM003)
GM 1/2 in. and Larger - Two threaded plugs (GM005 -
GM020)
Shipping Weight:
1 lb. (.45 kg)
13