Proper cleaning is mandatory for long life.
Herbicide equipment requires cleaning much
like spray paint equipment. Many herbicides
will harden in a very short period of time and
cause severe damage. Improper cleaning will
also void the warranty.

The meter should be flushed with water at the
end of each day.

NOTE:  Meter reading will change as meter is

flushed.

Remove the pump and meter from herbicide
container. Insert suction pipe into water. Turn
pump on and alternate opening and closing
nozzle until water is free of herbicide residue.
After flushing, let water drain out of suction pipe
and open nozzle to clear most of the water out
of the hose and meter.

NOTE:  For best results, disassemble, clean

and inspect annually and replace seals.

Drain herbicide from meter and flush with wa-
ter as described under maintenance.

1. To  replace counter and gear assembly,

nutating disc and corresponding seals; re-
move knob (111028-2).

2. Remove 2 screws (904002-13) connecting

the coverplate to the main housing. Then
remove coverplate.

3. Remove 4 screws (904002-12) which hold

counter assembly and then remove this
assembly.

4. Remove 2 screws (904003-37) to remove

the nutator disc assembly (if needed).

5. To reassemble, reverse the above proce-

dure, ensuring that all seals are carefully
in place.

MAINTENANCE

W A R N I N G

DO NOT STORE METER WITH WATER IN
CAVITIES. For prolonged periods of stor-
age, flush and drain as outlined above.
See Assembly/Disassembly instructions
for inspection of counter assembly and
nutator disc assembly. Inspect and clean
any remaining herbicide residue from
meter interior, reinstall covers and fill
meter with ethylene glycol (antifreeze).

ASSEMBLY / DISASSEMBLY

For warranty consideration, parts, or other ser-
vicing information, please contact your local dis-
tributor. If you need further assistance, call the
GPI Customer Service Department in Wichita,
Kansas, during normal business hours.

1-800-835-0113

To obtain prompt, efficient service, always be
prepared with the following information:

1. The model number of your meter.

2. The serial number or manufacturing date

code of your meter.

3. Specific information about part numbers and

descriptions.

For warranty work always be prepared with your
original sales slip or other evidence of purchase
date.

Returning Parts

Please contact the factory before returning any
parts. It may be possible to diagnose the trouble
and identify needed parts in a telephone call or
letter. GPI can also inform you of any special
handling requirements you will need to follow
covering the transportation and handling of
equipment which has been used to transfer haz-
ardous liquids.

CAUTION: Do not return meters without spe-

cific authority from the GPI Customer Ser-
vice Department. Due to strict regulations
governing transportation, handling, and
disposal of hazardous liquids, GPI will not
accept meters for rework unless they are
completely free of chemical.

SERVICE

Summary of Contents for FM100H

Page 1: ... Burnished aluminum finish Registers up to 999 9 gallons 9 999 litres per delivery Totalizer registers up to 99 999 gallons 999 999 litres 50 psi 3 4 bar maximum working pressure Large reset knob Operating range 4 20 GPM 15 75 LPM Inlet and outlet thread 1 NPT or 1 BSPP Approved Chemicals for Model FM100H Herbicide Meter The GPI Herbicide Meter has been tested and approved for most mini bulk herbi...

Page 2: ...prolonged periods of stor age flush and drain as outlined above See Assembly Disassembly instructions for inspection of counter assembly and nutator disc assembly Inspect and clean any remaining herbicide residue from meter interior reinstall covers and fill meter with ethylene glycol antifreeze ASSEMBLY DISASSEMBLY For warranty consideration parts or other ser vicing information please contact yo...

Page 3: ...er s option replacing or repairing defective Goods subject to limitations hereinafter provided or refunding the purchase price for such Goods theretofore paid by the Buyer and Buyer s exclusive remedy for breach of any such warranties will be enforcement of such obligations of Manufacturer The warranty shall extend to the purchaser of this product and to any person to whom such product is transfer...

Page 4: ...11029 1 Strainer Coverplate 1 10C ILLUSTRATED PARTS DRAWING 5252 East 36th Street North Wichita KS USA 67220 3205 TEL 316 686 7361 FAX 316 686 6746 A Great Plains Ventures Subsidiary www gpi net 1 800 835 0113 Rev A 921626 2 11 05 Item No No Part No Description Req d 1 111034 1 Decal Gallon 1 111034 3 Decal Litre NPT 1 2 904002 13 Screw Sems 8 32 x 5 16 in 2 3 111006 1 Counter Cover Gallon 1 11100...

Reviews: