Conclusion: with a dynamometer, loading the belt branch with 75 N as indicated in fig. 14, a “te” bend of aproximately
10.8 mm is obtained.
Note
1
: Unless otherwise stated by the supplier of the belts, control of proper pull and its relative re-tensioning should be
performed after no less than 30 minutes of motion necessary for the normal asjustment of the belts. Best performance
and durability will be achieved with proper tensioning.
Note
2
: In case of necessity or for routine maintenance, never replace a single belt, but the complete set.