4. After the month and day has been set, the time setting will appear on the screen with the hour

flashing. Press the “MEM” button to change the hour

(NOTE: Time is in 24 hour format)

. Press

the “SET” button once you have reached the desired hour. After hour has been set, the minute
setting will be flashing, take the same steps to set the minute setting.

SETTING THE UNIT OF MEASUREMENT

You can set up your monitor to measure pressure in either kPa or mmHg.

1. After the date and time has been set up, a “0”, with “mmHg” below, will display on the screen.

To change the unit of measurement, press the “MEM” button then press the “SET” button to
save that setting.

SETTING THE POSITIONING SENSOR

The positioning sensor is a new feature in blood pressure monitors that tells the user whether

the position of the blood pressure monitor is too high or too low. The positioning sensor symbol is
the shape of a heart with two arrows going up or down.

1. After the unit of measurement has been set, the word “ON” will be displayed along with the

positioning sensor symbol will be displayed on the screen. This means that the positioning
sensor is on, press “SET” to keep the positioning sensor on. If you wish to turn the positioning
sensor off, press the “MEM” button. Press “SET” to save the setting.

SETTING THE VOICE FUNCTION

The Voice function is a new feature in our blood pressure monitor that speaks to you. It will

tell you whether the cuff is too high or too low and will read out your results.

Day Setting

Month Setting

SET

MEM

SET

MEM

SET

BP213

BP213

BP213

BP213

Minute Setting

Hour Setting

SET

MEM

SET

MEM

BP213

BP213

BP213

BP213

MEM

BP213

SET

BP213

Summary of Contents for GW22059

Page 1: ...W22059 GoWISE USAR www gowiseusa com info gowiseusa com 1 855 233 9199 Thank you for purchasing this GoWISE USA Blood Pressure Monitor To assure correct use of this monitor read these instructions car...

Page 2: ...F RECORDS Recall records 10 Delete records 11 INFORMATION FOR USER Tips for operation 12 Maintenance 13 ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure 13 What is the standard b...

Page 3: ...xtremi es other than the wrist or for fluctua s other than obtaining a blood pressure measurement Do not confuse self monitoring with self diagnosis thisunit allows you to monitor your blood pressure...

Page 4: ...lood pressure High pressure result Diastolic blood pressure Low pressure result BPM Motion will result in inaccurate measurements Memory If M shows the displayed measurement values is from the memory...

Page 5: ...acement of batteries 1 Slide off the battery cover 2 Install the batteries by matching the correct polarity as shown 3 Replace the cover Body Cuff Voice Display Battery Compartment Wrist Cuff Setting...

Page 6: ...calculates standard The device displays a warning signal with the reading to indicate the detection of irregular heartbeat when the di erence of th e intervals is over 25 HOW TO SET UP YOUR BLOOD PRE...

Page 7: ...ure in blood pressure monitors that tells the user whether the position of the blood pressure monitor is too high or too low The positioning sensor symbol is the shape of a heart with two arrows going...

Page 8: ...elow the SND ON on the display is the volume level After you turn the voice function on press MEM continually to turn up the volume it can be set between levels 1 and 7 then press the power button to...

Page 9: ...y measurements at approximately the same time and same or as directed by a physician Start a measurement 1 Choose a user then press 2 Press the to turn on the monitor If the cuff is not in the proper...

Page 10: ...will show you the average value of all AM or morning readings 3 Press MEM again and it will show you the average value of all PM or afternoon evenings readings 4 Press MEM again to display each readin...

Page 11: ...delete all results by following these steps 1 When the unit is o switch to the user you want to delete records for then press Press MEM briefly to turn on the appropriate screen Then press and hold ME...

Page 12: ...er these Wait at least 1 hour r dinner or drinking Do not measure immediately r tea co ee smoking Wait at least 20 minutes er taking a bath Do not measure in very cold environment Do not measure when...

Page 13: ...r Avoid dusty environment and unstable temperature Avoid washing the cu ABOUT BLOOD PRESSURE What are systolic pressure and diastolic pressure Systolic blood discharging Diastolic blood entering arter...

Page 14: ...160 179 180 DIA 80 80 84 85 89 90 99 100 109 110 CAUTION The standard blood pressure classification provided above is for GENERAL INFORMATION ONLY YOU MUST CONSULT YOUR PHYSICIAN or a licensed healthc...

Page 15: ...eadings because the settings and properties are not all the same In addition blood pressure changes throughout the day due to circumstances such as stress or weather When taking your blood pressure at...

Page 16: ...ies power are too low The course of inflating appears error When measurement fails Correction Cause Symbol Replace both of the worn batteries with two new ones Blood pressure varies constantly Many fa...

Page 17: ...kPa 3 Digits Display Memory IHB Heartbeat Low Battery etc 3 mmHg 0 4kPa 5 of reading Pulse Internal power supply appliance type B LCD Indication Symbol Memory 180 2 90 Sets Measurement Values Automati...

Page 18: ...l not be liable for loss of use or any other incidental consequential or indirect costs expenses or damages There are no express warranties except as listed above This warranty gives you specific lega...

Reviews: