Goulds STS21V Instruction Manual Download Page 8

GOULDS WATER TECHNOLOGY LIMITED WARRANTY

This warranty applies to all water system pumps and related accessories manufactured and/or supplied by Goulds Water Tech-
nology, provided the installation is in accordance with the Instruction Manual issued by the Manufacturer.

Any part or parts found to be defective within the warranty period shall be replaced at no charge to the buyer or any subse-
quent owner during the warranty period. The warranty period shall exist for a period of twelve (12) months from the date of 
installation or eighteen (18) months from the date of manufacture, whichever is shorter.

A consumer who believes that a warranty claim exists must contact the authorized Goulds Water Technology dealer from 
whom the equipment was originally purchased and furnish complete details regarding the claim for warranty.

The warranty excludes:
(a)  Labor, transportation and related costs incurred by the consumer to make the alleged defective equipment available to the 
dealer for inspection.;
(b)  Re-installation costs of repaired equipment;
(c)  Reinstallation costs of replacement equipment;
(d)  Consequential damages of any kind; and,
(e)  Reimbursement for loss caused by interruption of service.

There are no warranties, expressed or implied, except such warranties as are definitely set forth herein. The Company shall 
not be liable for damage or wear to pump caused by abnormal conditions, failure to properly prime or to operate pump 
without flow or caused by corrosives, abrasives, or foreign objects. No obligations other than those herein set forth shall be 

binding upon the company.

Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. 
Teflon is a registered trademark of Dupont.

© 2012 Xylem Inc.    IM236  Revision Number 1     July 2012

Xylem, Inc.

2881 East Bayard Street Ext., Suite A
Seneca Falls, NY 13148
Phone: (866) 325-4210 
Fax: (888) 322-5877
www.xyleminc.com/brands/gouldswatertechnology

Australia Korea

Xylem Water Systems Australia Pty. Ltd. 

Xylem Water Solutions Korea Co., Ltd.

Unit 3/1 Federation Way, Chifley Business Park 

4F, Dong-A Building , 789

Chifley Business Park 

Yeoksam, Gangnam

Mentone, Victoria 3194, Australia  

Seoul, 135-929, Korea

Tel: +61.3.9551.7333 Fax: +61.3.9551.0321 

Tel: +82.2.552.0553 Fax: +82.2.552.0557

Singapore Philippines

Xylem Water Solutions Singapore Pte Ltd. 

Xylem Water Systems International, Inc.

1 Jalan Kilang Timor, #06-06 

12 Ring Road, LISP II

Singapore 159303 

Calamba Laguna 4027, Philippines

Tel: +65.6681.0166 Fax: +65.6681.0168 

Tel: +63.49.545.6810 Fax: +63.49.545.6817

Summary of Contents for STS21V

Page 1: ...Sump Pumps INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM236 ...

Page 2: ... code The pump must be connected to a dedicat ed electrical circuit protected by a prop erly sized circuit breaker or fuses Install a disconnect where required by code Code questions should be directed to your electrical inspector See Chart 1 for specific information Disconnect electrical power before install ing or servicing the pump The motor s automatic thermal overload protection may allow an ...

Page 3: ... never by the power cord Place the pump against the basin wall so the switch is to the center See Installation Data 3 PIPING 4 INSTALLATION IN SUMP 1 GENERAL INFORMATION 1 1 Sump pumps are designed to operate inter mittently and usually seasonally It is recom mended that you test the pump before your rainy season begins to insure that the pump and switch are operating properly 1 2 We suggest insta...

Page 4: ... debris children or pets falling into the basin See Basin Style in Section 2 3 6 SEASONAL SERVICE MAINTENANCE 6 1 If your sump pump only operates seasonally and then sits idle for months it is recom 5 OPERATION 6 SEASONAL SERVICE MAINTENANCE mended that you test the pump before your rainy season begins Fill the sump with water and check for debris and proper switch operation Remove any debris whic...

Page 5: ...ion Basin Solids Weight Style Diameter Size STS21V 0 25 1 60 115 2 5 amps Vertical 20 1 12 3 16 9 lbs STS31V 0 33 1 60 115 4 5 amps Vertical 20 1 12 3 16 9 lbs MODEL INFORMATION CHART 1 Suggested Pump Positioning in Sump Figure 1 Australian Plug Figure 2 INSTALLATION DATA INSTALLATION DATA MODEL INFORMATION CHART 1 ...

Page 6: ... General Pump Configuration Figure 4 Hose Adapter Figure 5 INSTALLATION DATA INSTALLATION DATA Typical Pump Installation in Sump Figure 3 PUMP ELECTRICAL PLUG CHECK VALVE FLOAT SWITCH UNION PUMPING RANGE ...

Page 7: ...7 NOTES NOTES ...

Page 8: ...for loss caused by interruption of service There are no warranties expressed or implied except such warranties as are definitely set forth herein The Company shall not be liable for damage or wear to pump caused by abnormal conditions failure to properly prime or to operate pump without flow or caused by corrosives abrasives or foreign objects No obligations other than those herein set forth shall...

Reviews: