WARNING
4. MAXIMUM OPERATING PRESSURE
(staging at 3500 RPM)
Pump
Stages
PSI / Bar
1SV
1-29
362 / 25
30
580 / 40
3SV
1-23
362 / 25
24-30
580 / 40
5SV
1-23
362 / 25
24-27
580 / 40
10SV
1-14
362 / 25
15-20
580 / 40
15SV
1-11
362 / 25
12-15
580 / 40
22SV
1-11
362 / 25
12
580 / 40
33SV
1-6
362 / 25
7-10
580 / 40
46SV
1-5
362 / 25
6-10
580 / 40
66SV
1-5
362 / 25
6
580 / 40
92SV
1-5
362 / 25
125SV
1-6
362 / 25
NOTE: Oval flange (1-22SV) maximum working
pressure is 232 psi (16 bar).
5. TEMPERATURE CAPABILITY
The e-SV pump is capable of pumping liquids within
the below temperature range:
Standard Seal
1SV-22SV
-22°F to 250°F (-30°C to 120°C)
33SV-125SV
-22°F to 250°F (-30°C to 120°C)
High Temperature Seal
1SV-22SV
-22°F to 300°F (-30°C to 149°C)
33SV-125SV N/A
NOTE: In order to provide adequate cooling for the
electric motor, the ambient temperature must
be 32º F to 104º F and the relative humidity at
104º F must not exceed 50%.
For temperatures above 104º F and for installations
sites located at elevation in excess at 3000 feet above
sea level it may be necessary to derate the motor
performance. Please contact your distributor/dealer for
assistance.
6. MINIMUM NOMINAL FLOW RATE
To prevent overheating of the internal pump com-
ponents, make sure that a minimum water flow is
always guaranteed when the pump is running.
For continuous operation the minimum flow rate
recommended is specified below.
Pump Size
Minimum Flow GPM
3500 RPM 1750 RPM 2900 RPM 1450 RPM
1SV
2
1
2
1
3SV
3
2
3
2
5SV
7
4
6
3
10SV
9
5
8
4
15SV
18
9
15
7
22SV
21
11
18
9
33SV
35
18
8
4
46SV
40
20
10
5
66SV
70
35
14
7
92SV
100
50
20
10
125SV
128
64
106
53
NOTE: If this cannot be achieved, then a bypass/
recirculate line is recommended.
Do not run the pump against a closed dis-
charge for longer than a few seconds.
7. NUMBER OF STARTS PER HOUR
For electric pumps coupled to motors supplied by
Goulds Water Technology, the maximum number
of work cycles (starts and stops) in one hour are as
follows:
HP
Max. Starts Per Hour*
Min. Run Time
Between Starts (sec)
0.5
24
120
0.75
24
120
1
15
75
1.5
13
76
2
12
77
3
9
30
5
8
83
7.5
7
88
10
6
92
15
5
100
20
5
110
25
5
115
30
4
120
40
4
130
50
3
145
60
3
170
75
3
180
* For more details, refer to technical manual.
If you use a different motor from the
standard one supplied by Goulds Water
Technology, please consult with the motor manu-
facturer to find out the maximum number of work
cycles allowed.
8. POWER SUPPLY REQUIREMENTS
Make sure that the supply voltages and
frequencies are suited to the characteristics
of the electric motor. Check the motor rating plate.
In general, the supply voltage tolerances for motor
operation are as follows:
U
N
Hz Phase
V
±%
60
1
230
10
60
3
230 / 460
10
60
3
460
10
1. TRANSPORTATION AND HANDLING OF
PACKED PRODUCT
The e-SV pump is packed in cartons
or wooden crates having different
dimensions and shapes.
Some cartons (the supporting base is made of
wood) are designed to be transported and handled
in the vertical position. Other cartons, as well as
the wooden crates, are designed to be transported
and handled in the horizontal position. Protect the
product against humidity, heat sources and mechani-
cal damage (collisions, falls, ...). Do not place heavy
weights on the cartons.
WARNING