background image

22

10. Clean all stainless steel parts with a clean cloth and if necessary some acetone. Check 
if the O-rings are still in good condition and replace if necessary. 

11. Reassemble motor to base and motor adapter to motor if necessary.

12. Submerge the station ary part of the mechanical seal in the 5 % soap solution and 
press it with your hands in the front side of the backplate. Apply an equally spread 
pressure and press it completely into place. 

13. Submerge also the rotating part of the same seal in the soap solution and slide it on 

the shaft (sealing face away from the vanes). Clean both sealing faces with a clean cloth. 

14. Put the key in the shaft and slide the impeller onto the shaft. Be careful the key fits 

in the keyway in the impeller and the rotating part of the mechanical seal re mains on its 

seat. 

15. Fasten the impeller screw. 

16. Replace the casing O-ring and pump casing (1). Fasten the bolts.

Seal replacement with damaged rotary o-ring

 

 

1. The upper part of the S-2 rotary is a pressed fit to the impeller shaft. A bearing puller  

 

 

may be used, or a tool available from Goulds Pumps may be purchased.

 

 

2. If using the Goulds Pumps tool, place the tool over the end of the impeller shaft,   

 

 

align the set screw with the holes in the seal sleeve and tighten them.

 

 

3. Use a 1/2-13 bolt through the front of the impeller to drive against the base of the  

 

 

tool and remove the seal sleeve.

 

 

4. To install a new seal sleeve on the impeller, use an arbor press to push the sleeve up  

 

 

the impeller shaft until the o-ring seats against the base of the impeller.

VII. Troubleshooting

Overview

 

This section provides a chart of potential problems along with their probable cause and 

remedies which will correct the problem.

Warning

 

Disconnect and lockout electrical power before attempting any maintenance. Failure to 

do so can cause a shock, burn or death.

Failure

Possible cause

Solution

There is no suction

Wrong direction of rotation

× 

Valve in suction line or pres­

× 

sure line closed

Synthetic  plugs  are  still  in 

× 

inlet or outlet

Insufficient de-aeration

× 

Change two terminals

× 

Open valves

× 

Remove plugs

× 

De­aerate better

× 

Open all valves completely, 

× 

decrease  pressure  in  dis­

charge vessel, make provi­

sions  so  that  no  liquid 

column  can  be  built  up  on 

the outlet of the pump

Summary of Contents for GSP Series

Page 1: ...ITT Goulds Pumps Models GSP Installation Operation and Maintenance Instructions Goulds Pumps is a brand of ITT Corporation www goulds com Engineered for life Commercial Water IM206 ...

Page 2: ...al Drawings 24 Appendix 25 Product code structure 25 Owners Information Complete this information for your records Model number and serial number may be found on the tag mounted to the pump casing Model Number _______________________________ Serial Number _________________________________ Dealer ______________________________________ Dealer phone number _______________________ Date of purchase ___...

Page 3: ...configurations Most assembly disassembly and inspection procedures are the same for all the pumps However where there are differences they are called out separately within the manual The design materials and workmanship incorporated in the construction of Goulds pumps makes them capable of giving long trouble free service The life and satisfactory service of any mechanical unit however is enhanced...

Page 4: ...ch if not avoided could result in minor or moderate injury Note Indicates a potential situation which if not avoided may result in undesirable results or state Indicates a practice not related to personal injury Electrical Hazard Indicates the possibility of electrical risks if direction are not applied in a proper manner Environmental safety Preventive measures for the working area Always keep th...

Page 5: ...isks of electric shock or arc flash hazards Product and product positioning requirements Observe these requirements for the product and the product positioning Never operate a pump unless safety devices are installed Three phase motors must have a properly sized starter with properly sized heaters to provide overload and undervoltage protection Single phase motors have built in overload protectors...

Page 6: ...duct Never work alone Stay clear of suspended loads Always lift the product by its lifting device Beware of the risk of a sudden start if the product is used with an automatic level control Beware of the starting jerk which can be powerful Rinse the components in water after disassembling the pump Do not exceed the maximum working pressure of the pump Do not open any vent or drain valves or remove...

Page 7: ... Receiving The pump should be uncrated or unboxed when it is received so that it can be completely inspected Carefully check that everything is in good order Make notes of damaged or missing items on the receipt and freight bill File any claims with the transportation company as soon as possible Storage Short Term For storage of less than six months the normal packaging procedures used by Goulds P...

Page 8: ...s operators to insure the purity of their process and the cleanliness of their plant to meet both local and national health and safety regulations Not all products marked 3A meet these design and clean ability standards Mechanical seals are FDA approved and several versions of the pump have EHEDG European sanitary certification Pump impellers are fully open and either threaded or key driven and he...

Page 9: ...er hour 20 evenly distributed with standard across the line start Unlimited with soft starter or drive Connections The following table shows the discharge and suction sizes in inches for each of the GSP pumps The Pump designation is the first three characters of the pump model number Pump Designation Fitting Size discharge x Suction Nominal Impeller S1A 1 x 1 5 5 S1B 2 x 2 5 4 S2A 1 5 x 2 7 S2B 2 ...

Page 10: ...uate for portable use where the pump may be moved to various places in the plant based on process requirements Optional legs are available with flanged bases which can be used for permanent mounting to the floor Hold down bolts should be sunk in concrete and aligned with the holes in the flanges When the concrete has dried tighten nuts to keep the pump firmly in position NOTICE Do not install with...

Page 11: ...the Hydraulic Institute Standards and should be reviewed prior to installation Warning Never draw piping into place by using force on the suction and discharge connections of the pump This may impose dangerous strains on the unit causing misalignment poor operation and physical injury and damage to the equipment 1 All piping must be supported independently of and line up naturally with the pump su...

Page 12: ...ormance curve for your pump to determine NPSH required Properly installed suction piping is a necessity for trouble free pump operation Suction piping should be flushed BEFORE connection to the pump 1 Use of elbows close to the pump suction should be avoided There should be a minimum of two pipe diameters of straight pipe between the elbow and suction inlet Where used elbows should be long radius ...

Page 13: ...on strainer or suction bell MUST be at least three times the diameter of the suction 6 Ensure that the size and minimum submergence over the suction inlet is sufficient to prevent air from entering the pump through a suction vortex H min D D H min D D 1 5D min 3 0D min H min D min 2 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 H Min Submergence in feet H 1 2 3 4 5 6 7 8 9 10111213141516 V V Velocity in ...

Page 14: ...ing devices should be used to protect the pump from surges and water hammer if quick closing valves are installed in the system Final Piping Check After connecting the piping to the pump rotate the motor shaft to make sure that there is no binding Wiring Warning Install ground and wire according to local and National Electrical Code requirements Install an all leg electrical power disconnect switc...

Page 15: ...everal different methods of priming can be used depending upon type of installation and service involved Warning GSP pumps are not self priming and must be fully primed at all times during operation Loss of prime can lead to excessive heat and severe damage to the pump and seal Flooded suction 1 Slowly open the suction valve 2 Open air vents on the suction and discharge piping until liquid flows o...

Page 16: ...ot quickly attained stop driver re prime and attempt to restart 4 Slowly open discharge valve until the desired flow is obtained Caution Observe pump for vibration levels bearing temperature and excessive noise If normal levels are exceeded shut down and resolve 5 After stabilizing the system at normal operating conditions check the piping and adjust supports if needed Operation General considerat...

Page 17: ...andling hazardous and or toxic fluids proper personal protective equipment should be worn If pump is being drained precautions must be taken to prevent physical injury Pumpage must be handled and disposed of in conformance with applicable environmental regulations VI Maintenance Overview This section covers the procedures precautions and schedule for maintenance of your Goulds pump A routine maint...

Page 18: ...t to grease every 2000 operating hours when the ambient temperature is 25 C If the ambient temperature is 40 C the interval must be halved Note When re greasing there is danger of impurities entering the bearing housing The grease container the greasing device and fittings must be clean Note The bearing temperature usually rises after re greasing due to an excess supply of grease Temperatures will...

Page 19: ... the residue hardening fat whereas higher temperatures lead to denaturising of proteins which are very difficult to remove Pulsating the liquid flow switching on and off the pump can im prove the cleaning The pre rinsing liquid is nearly always drained The pre rinse can be done with tap water and is very important because it can remove most of the residue Cleaning with detergent and alkali This cl...

Page 20: ... Note Before disassembling the pump for overhaul ensure all replacement parts are available Warning Lock out power supply to driver motor to prevent accidental startup and physical injury 1 Shut off all valves controlling flow to and from the pump 2 Drain liquid from piping and flush pump if necessary Warning Allow all system and pump components to cool before handling them to prevent physical inj...

Page 21: ...the motor The impeller should have a 5mm clearance to the backplate 14 Put the casing O ring and pump casing back on the front of the pump Fasten the bolts Refer to exploded view drawings on page 24 for added detail S2 Series For the replacement of the mechanical seal a 5 soap solution is needed 1 Remove casing bolts 2 Remove back pull out assembly from casing On close coupled units the back pull ...

Page 22: ... bearing puller may be used or a tool available from Goulds Pumps may be purchased 2 If using the Goulds Pumps tool place the tool over the end of the impeller shaft align the set screw with the holes in the seal sleeve and tighten them 3 Use a 1 2 13 bolt through the front of the impeller to drive against the base of the tool and remove the seal sleeve 4 To install a new seal sleeve on the impell...

Page 23: ...s Cool down liquid Fill up tank or lower pump Pump flow too high Friction losses too low Close valve in discharge pipe Pump blocked Pump wrongly assembled Foreign body in the pump Disassemble and assemble in the correct way Clean Motor uses too much current Amperes Wrong direction of rotation Flow too high Pump blocked Voltage too low Change two terminals See above See above Repair electrical fail...

Page 24: ...assembly 2 15 O rings 4 16 Foot motor base 4 Wet End Only Location Description Quantity 2 Casing 1 3 Impeller 1 5 O ring 1 7 Back plate 1 Base with Cover Location Description Quantity 15 O rings 4 16 Foot motor base 4 17 Base assembly 1 18 Motor cover 1 19 Washer 4 20 Hex head cap screw 4 Base with Cover VIII Parts Listing and Cross Sectional Drawings Overview This section provides cross sectional...

Page 25: ...sure Trim Elastomer S 1 A 1 60 3500 1 C 0 5 1 115 208 230 1 ODP A 0 EPDM Car SilCar 1 B 2 60 3500 3 D 0 75 2 115 230 2 TEFC B 2 Viton Car SilCar 2 A 3 60 1750 1 E 1 3 230 4 PE ODP C 2 B 4 60 1750 3 F 1 5 4 230 460 5 PE TEFC D 2 C 5 50 2900 1 G 2 5 208 230 460 7 WD 2 D 6 50 2800 3 H 3 6 460 8 PE WD 2 E 7 1 50 1450 J 5 7 575 9 SS WD 2 F 8 3 50 1450 K 7 5 8 208 2 G L 10 9 208 230 2 H M 15 A 190 380 N...