![GOSUNCN ME3630 Series Command Reference Manual Download Page 35](http://html.mh-extra.com/html/gosuncn/me3630-series/me3630-series_command-reference-manual_2247368035.webp)
All Rights reserved, No Spreading without GOSUNCN Permission
34
AT Command Reference Guide of Module Product
ME3630
command may return ERROR.
<mode>: defines the operation to be done on the facility
0
unlock
1
lock
2
query status
<status>: the current status of the facility
0
not active
1
active
<passwd>: string type; shall be the same as password specified for the facility from the MT user interface or with command
Change PaCPWD
<class> is a sum of integers each representing a class of information:
2
data (refers to all bearer services; with <mode>=2 this may refer only to some bearer service if TA does not support
values 16, 32, 64 and 128)
8
short message service
16
data circuit sync
32
data circuit async
64
dedicated packet access
128 dedicated PAD access
Example
AT+CLCK=?
+CLCK: ("AB","AC","AG","AI","AO","IR","OI","OX","SC","FD","PN","PU","PP","PC","PF")
OK
AT+CLCK="SC",1,"1234" //lock the SIM card
OK
AT+CLCK="SC",0,"1234"
OK
5.2.
AT+CPWD Change Password
Execution command sets a new password for the facility lock function defined by command Facility Lock +CLCK.
Test command returns a list of pairs which present the available facilities and the maximum length of their password.
Command
Response
+CPWD=<fac>,<oldpwd>,<newpwd>
<CR><LF>OK<CR><LF>
or
<CR><LF>+CME ERROR: <err><CR><LF>
+CPWD=?
<CR><LF>+CPWD: list of supported (<fac>,<pwdlength>)s<CR><LF>
<CR><LF>OK<CR><LF>
or
<CR><LF>+CME ERROR: <err><CR><LF>
Parameter
<fac>:
"P2"
SIM PIN2
Refer to command Facility Lock +CLCK for other values