GMC-I Messtechnik GmbH
85
8.2
Queriable Functions and Parameters
1)
“off” as in “Stop”, SEQ. function always open
2)
“/” instead of “;” within
txt
3)
or front panel display selectable / possible
4)
LED
5)
Si 91
txt or
Si 92
txt
6)
Strt
n
or
Stop
n
7)
Manual:
RCL
n
and scroll through parameters with [SELECT] key (indirect)
8)
Status indicated by blinking “LOCKED/SEQ” LED,
rrep and rcl with <SELECT> key
9)
in general: length = ((n2-n1+1)x38)-1 characters, with n1, n2 also as start/stop address
Read out via interface Response string for remote operation (example):
Resp.
string
length
Expla-
nation
in
Chapter
on Page
Fr
on
t panel
3)
RS 232C
IEEE 488
10 characters 10 characters 10 characters
Me
asur
e
d
V
a
lue Q
u
er
y
IMA
X?
Max. measured current value from Min-Max memory [A]
X
X
X
IMAX +15.4
400
13
IMI
N?
Min. measured current value from Min-Max memory [A]
X
X
X
IMIN -00.0
100
13
IO
UT?
Momentary measured current value [A]
X
X
X
IOUT +11.5
100
13
MO
DE?
Momentary output operating mode (control mode)
X
4)
X
X
MODE CV
8
CV = constant voltage, CC = constant current
OL = overload, OFF = output deactivated
POU
T?
Momentary measured power value [W]
X
X
X
POUT +0662
.7
12
UMA
X?
Max. measured voltage value from Min-Max memory [V]
X
X
X
UMAX +021.
310
13
UMI
N?
Min. measured voltage value from Min-Max memory [V]
X
X
X
UMIN +021.
280
13
UO
UT?
Momentary measured voltage value [V]
X
X
X
UOUT +021.
300
13
Fu
nc
tion-Specific
De
vi
ce
Q
u
er
ie
s
DE
LAY?
Selected delay time for OCP function
X
X
X
DELAY 12.0
0
11
DI
SPLAY?
On-off status of the 7-segment displays
X
X
X
DISPLAY ON
11
IL
IM?
Selected current setting range limit [A]
X
X
X
ILIM +20.0
000
13
IS
ET?
Selected current setpoint value [A]
X
X
X
ISET +18.0
000
13
MI
NMAX?
Min-Max memory enable status
X
X
X
MINMAX ON
10
OC
P?
Selected current limiting function
X
X
X
OCP OFF
7
OU
TPUT?
Output on-off status
X
4)
X
X
OUTPUT ON
10
OVS
ET?
Selected overvoltage protection trigger value [V]
X
X
X
OVSET +050
.0
12
POW
ER_ON?
Selected power-up status
X
X
X
POWER_ON R
ST
12
RE
PETITION?
Selected number of repetitions for the sequence function
X
X
X
REPETITION
000
14
SEQ
UENCE?
Sequence function status
8)
X
X
SEQUENCE H
OLD,255,11
1
21
SI
G1_SIG2?
Selected function for signal outputs at the analog interface
X
5)
X
X
SIG1_SIG2
OUT,MODE
19
SS
ET?
Selected switching signal for the sequence function
X
X
X
SSET OFF
8
STA
RT_STOP?
Selected start and stop memory addresses for the sequence function
X
6)
X
X
START_STOP
020,115
18
STO
RE?
Recall data from start address to stop address from sequence / limit value memory
7)
X
X
STORE 014,
+015.500,+
03.0000,09
STO
RE?
n
Recall data from address n from sequence / limit value memory
STO
RE?
n1,n2
Recall data from address n1 to address n2 from sequence / limit value memory
STO
RE?
n1,n2,txt
Recall data from address n1 to address n2 from sequence / limit value memory with tab
37
9)
n, n1, n2:
11, 12, ... , 255 (memory address), n2
n1, optional
txt:
tab (optional)
.70, ON
TD
EF?
Selected default time for the sequence function
X
X
X
TDEF 10.00
10
T_M
ODE?
Selected trigger input function
X
X
X
T_MODE OUT
10
TS
ET?
Selected dwell time for the sequence function
X
X
X
TSET 00.10
10
UL
IM?
Selected voltage setting range limit [V]
X
X
X
ULIM +035.
000
13
US
ET?
Selected voltage setpoint value [V]
X
X
X
USET +021.
300
13
Ge
ner
a
l Que
ries
*
DDT?
DDT function memory content
X
X
USET +010.
000;ISET +
18.0000
1...80
*
IDN?
Device ID
X
X
GOSSEN-MET
RAWATT,SSP
32N040RU00
49
6P,XXXXXXX
XX,04.001
*
LRN?
Complete settings
X
X
ULIM +020.
000;ILIM +
20.0000;OV
202
SET +025.0
;OCP OFF;D
ELAY 12.00
;USET +019
.300;ISET
+18.0000;O
UTPUT
ON;
POWER_ON R
ST;MINMAX
ON;TSET 0
0.10;TDEF
10.00;REPE
TITION 000
;START_STO
P 020,115;
T_MODE OUT
;DISPLAY O
FF
*
TST?
Start self-test results query
X
X
0
1
0 = error-free, 1 = error