GOSSEN METRAWATT GMBH
25
Power Supply
Batteries
2 ea. 1.5 V mignon cell
alkaline-manganese per IEC LR6
or zinc-carbon per IEC R6
Service Life
with alkaline-manganese batteries: approx. 100 hours
with zinc-carbon batteries:
approx. 50 hours
Battery Test
symbol is displayed automatically if battery voltage
drops to below approximately 2.3 V.
Battery Saving Circuit
The instrument is switched off automatically if the measured value remains
unchanged for a period of approximately 10 minutes, and if none of the control
elements are operated during this period. Automatic shutdown can be disabled.
Fuses
Range up to 300 mA
FFF1A/380VAC, 5 mm x 20 mm
Switching capacity 10 kA at 380 V AC and ohmic load;
protects, in combination with power diodes, all current
measuring ranges up to 300 mA
15 A range
– Resettable 15A/240VAC/50VDC miniature circuit breaker,
– additionally, a fuse link has been joint in series with
the m.c.b.: T16A/500VAC, 6.3 mm x 32 mm
Switching capacity 1.5 kA at 500 V AC and ohmic load
Electrical Safety
Safety Class
II per IEC/EN 61010-1:2001/VDE 0411-1:2002
Measurement Category
II
Operating Voltage
300 V
Contamination Level
2
Test Voltage
2.3 kV~ per IEC/EN 61010-1:2001/VDE 0411-1:2002
Electromagnetic Compatibility (EMC)
Interference Emission
EN 61326:2002 Class B
Interference Immunity
EN 61326:2002
IEC 61000-4-2:1995/A1:1998, Feature A
8 kV atmospheric discharge
4 kV contact discharge
IEC 61000-4-3:1995/A1:1998, Feature B; 3 V/m
Ambient Conditions
Operating Temp.
−
10
°
C
…
+50
°
C
Storage Temperature
−
25
°
C
…
+70
°
C (without batteries)
Relative Humidity
max. 75%, no condensation allowed
Elevation
to 2000 m
Deployment
indoors, outdoors: only within the specified
ambient conditions