22
GMC-I Messtechnik GmbH
Control Functions
4.4
Measured Value Storage: DATA (auto-hold / compare)
An individual measured value can be automatically “frozen” with
the DATA function (auto-hold). This is useful, for example, when
contacting the measuring points with the test probes requires
your full attention. After the measuring signal has been applied
and the measured value has settled in in accordance with the
“condition” listed in the table below, the measured value is frozen
at the digital display and an acoustic signal is generated. The test
probes can now be removed from the measuring points, and the
measured value can be read from the digital display. If the mea-
suring signal falls below the value specified in the table, the func-
tion is reactivated for storage of the next value.
Measured Value Comparison (DATA compare)
If the currently frozen value deviates from the first saved value by
less than 100 digits, the acoustic signal is generated twice. If devi-
ation is greater than 100 digits, only a brief acoustic signal is gen-
erated.
Note
The selected measuring range cannot be manually changed
as long as the DATA function is active.
The DATA function is deactivated by pressing and holding the
DATA/MIN/MAX
key (approx. 1 second), when the measuring func-
tion is changed or when the instrument is switched off and back
on again.
1
Reactivation results from falling short of specified measured value limits.
2
Two acoustic signals are generated the first time a measured value is saved as a reference value.
For subsequent data hold, two acoustic signals are only generated if the currently frozen value deviates
from the
first
saved value by less than 100 digits.
Key: MV = measured value, MR = measuring range
DATA
Function
Press
DATA /
Min-Max
Condition
Response from
Instrument
Measuring
Function
Measuring
Signal
Display
Acous-
tic
MV
Digital
DATA
Activate
Brief
Blinks
Once
Save
(stabilized
measured
value)
V, A, Hz, dB,
F, %
> 10%
r MR
Is dis-
played
Static
Once
Twice
2
0L
Reactivate
1)
V, A, Hz, dB,
F, %
< 10%
r MR
Stored
MV
Blinks
=
0L
Change to
Min-Max
Brief
See table in section 4.4.1
Exit
Long
Is
cleared
Is
cleared
Twice
V, A, Hz
t [s]
300000
30000
Activated
Reactivated
Save
Save
of Measuring Range
D
D
100 %