Transient Operation Menu
Press
key in desired mode to enable its transient operation, and press
key to enter into transient setting menu, which is
shown as below:
Note
Transient operation may be used in CC, CV, and CR modes.
1.6.4
List Operation Menu
Press
key and
key to enter into the list operation menu, which is shown as below:
Press
▲
and
▼
keys in list operation menu to select Data: <New/Edit>, and select New or Edit with the knob or
◄
and
►
keys.
Then press key to
Enter
into sequence data editing status, which is shown as below:
MODE
:
CPC
POWR
:
0.000W
Constant power-current source mode
Immediate power level
Function
Description
Example
LevelL
Transient low level
1.000 A
LevelH
Transient high level
2.000 A
TimeL
Time for transient low level
600.00 ms
TimeH
Time for transient high level
600.00 ms
TimeR
Time for transient rising edge
0.01 ms
TimeF
Time for transient falling edge
0.01 ms
MODE
Continuous (Cont) Pulse (Puls) Toggle (Togg)
Cont
Function
Description
No.
Select sequence (list) number (0-6)
Memo
Sequence memo (10 characters)
Data: <New/Edit>
Create a new or edit an existing sequence
Count
Cycle times (1-65535)
Chain: Off
Sequence number to be chained with (0-6, off)
Function
Description
01. 10000.00000s
CCH 5.000A
Sequence (list) number
Time
Mode
Setting value
Function / Parameter
Description