2. Connect the sensor jack to the camera sensor socket, put the sensor 
end in cotton diaper if you select the Bed-wetting Sensor detection.

* Specialists recommend the sensor is not suitable  
for disposable panty diaper; and not suitable for 
touching skin directly.

Motion Alarm Setup:

It refers to the alarm against various movements. If you slide the 
alarm setting switch to Motion position, and select  Sensitivity 
switch. Afterward, the system enters the motion alarm mode. When
a movement is actually detected, the alarm begins until you press
the Eliminate Alarm Button. After less than 1 minute, the motion
alarm enters the next alarm circle.

Sound Alarm Setup:

It refers to the alarm against sound .  If you slide the alarm setting 
switch to Sound position, and select  Sensitivity switch. Afterward, 
the system enters the sound alarm mode. When the sound is actually 
detected, the alarm begins until you press the Eliminate Alarm Button. 
After less than 1 minute, the sound alarm enters the next alarm circle. 

Sensor Alarm Setup:

It refers to the alarm against bedwetting.  If you slide the alarm 
setting switch to Sensor position, and select  Sensitivity switch. 
Connect the sensor to camera and diaper. Afterward, the system enters 
the sensor alarm mode. When the bedwetting and  water is actually 
detected, the alarm begins until you press the Eliminate Alarm Button. 
After less than 1 minute, the motion alarm enters the next alarm circle.

Off Alarm Setup:

It refers to the abandonment of the alarm function. If you slide the 
alarm setting switch to Off position. The alarm function is disabled.

 

Note:

When the camera is powered on by dry batteries and directly plugged
in by the adapter, the alarm function fails to work. If this is the case,
please slide the power Off and back again to On, the alarm function
is successfully activated.

 

Summary of Contents for GB8209

Page 1: ......

Page 2: ...Contents 1 Packing List 2 Diagram 3 Structure 4 Installation 5 Specification 6 FCC and EU 1 1 2 3 8 9 ...

Page 3: ...1 Packing List 2 Diagram Sensor for camera 8209AW means GB8209 GB7609 ...

Page 4: ...a Antenna Speaker IR LEDs TFT LCD Power On Off Alarm Switch Sensitivity Switch Channel Switch Battery Cover Battery Cover Lens Power Socket Channel Indicator AV Out Volume Switch Power On Off Sleep Button Power Socket Sensor Socket Channel Button Eliminate Alarm Button ...

Page 5: ...also use dry battery as power supply Please load 4 AA batteries to the battery compartment at the back of camera with their polarities matched The AC adapter will work instead of batteries after it is plugged If the camera is not used for a long period of time please unplug the adapter and remove the batteries Avoid short circuit of the battery Continue working for 5 hours IR OFF ...

Page 6: ...erence avoidance 2 Press channel buttonof the receiver toselect the same channel as the camera The pictures willbe displayed on thescreen 30 30 4 1 2 Camera channel setup 4 1 3 Camera alarm setup CH4 CH3 CH2 CH1 Off Motion Sensor Sound Low Middle High Ch1 2 414MHz Ch2 2 432MHz Ch3 2 450MHz Ch4 2 468MHz 1 The camera provides Motion Detection Sensor Detection Sound Detection Each mode can separately...

Page 7: ...rs the sound alarm mode When the sound is actually detected the alarm begins until you press the Eliminate Alarm Button After less than 1 minute the sound alarm enters the next alarm circle Sensor Alarm Setup It refers to the alarm against bedwetting If you slide the alarm setting switch to Sensor position and select Sensitivity switch Connect the sensor to camera and diaper Afterward the system e...

Page 8: ...el Note This receiver can also work on dry battery Please load 4 AA batteries to the battery compartment at the back of receiver with their polarities matched The AC adapter will work instead of batteries after it is plugged If the receiver is left unused for a long period of time please unplug the adapter and remove the batteries Avoid short circuit of the battery Continue working for 5 hours ...

Page 9: ...s CH button to select the appropriate channel 3 Channel Looping Hold the CH button for three seconds to enter the loop mode All the available channels will be displayed one by one default interval is 5 seconds 4 Sleep Mode Press the Sleep Button to shut down the LCD display and keep the voice function Press the button again and recall the normal working mode It can save energy and help your sleepi...

Page 10: ... Detection Sensitivity Consumption Current Max Power Supply Dimensions W D H Weight About LCD Screen Type Effective Pixels Receiving Sensitivity Consumption Current Max Battery Working Time Power Supply Dimensions W D H Weight About ISM 2 400 2 483 MHz 10mW CE 2mW FCC 2 414MHz 2 432MHz 2 450MHz 2 468MHz 100m Min FM 10 50 14 122 85 CMOS PAL 720 480Pixels NTSC 724 576 Pixels 0Lux IR ON 5m 18M 5 hour...

Page 11: ...onditions 1 this device may not cause harmful interference 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ...

Page 12: ...h the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following m...

Reviews: