OM-00675
10 SERIES
OPERATION
PAGE C - 3
could result in personal injury or damage to the
equipment. If backflushing is absolutely neces
sary,
liquid pressure
must be limited to 50% of the
maximum permissible operating pressure shown
on the pump performance curve. (See Section E,
Page 1.) If the pump is fitted with a Gorman‐Rupp
double grease lubricated seal, the maximum in
coming pressure must be reduced to 10 p.s.i.
Pump Vacuum Check
With the pump inoperative, install a vacuum gauge
in the system, using pipe dope on the threads.
Block the suction line and start the pump. At oper
ating speed the pump should pull a vacuum of 20
inches (508,0 mm) or more of mercury. If it does
not, check for air leaks in the seal, gasket, or dis
charge valve.
Open the suction line, and read the vacuum gauge
with the pump primed and at operation speed.
Shut off the pump. The vacuum gauge reading will
immediately drop proportionate to static suction
lift, and should then stabilize. If the vacuum reading
falls off rapidly after stabilization, an air leak exists.
Before checking for the source of the leak, check
the point of installation of the vacuum gauge.
STOPPING
Never halt the flow of liquid suddenly. If the liquid
being pumped is stopped abruptly, damaging
shock waves can be transmitted to the pump and
piping system. Close all connecting valves slowly.
On engine driven pumps, reduce the throttle
speed slowly and allow the engine to idle briefly be
fore stopping.
Stopping
Reduce the throttle speed slowly, and allow the en
gine to idle briefly before switching the HAND‐OFF‐
AUTO switch to `OFF'.
If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.
After stopping the pump, close and lock the control
panel cover, or disconnect the positive battery
cable to ensure that the pump will remain inopera
tive.
Safety Shutdown System
The unit is equipped with a safety system to auto
matically shut down the engine under certain con
ditions. The engine will automatically shut down:
1. If the engine exceeds its safe operating tem
perature.
2. If the engine oil pressure drops below design
limits.
3. If the engine fails to start within a pre‐set peri
od of time.
4. If the engine speed exceeds the safe operat
ing range.
5. If the engine fan belt breaks.
Lights on the control panel will indicate which of the
safety features has caused the engine to shut
down.
Should any of the safety features cause the engine
to shut down,
the cause must be determined and
corrected
before putting the unit back into service.
The engine
will not
restart
until the HAND‐OFF‐
AUTO switch has been returned to the `OFF' posi
tion for at least 10 seconds.
All safety shutdown features are pre‐set at the fac
tory for optimum performance and safety;
do not
attempt to adjust these settings.
Never disconnect any of the safety shut
down features; this will void the warran
ty and could result in serious damage to
the unit and/or injury to personnel. Safe
ty shutdown features are pre‐set at the
factory; do not attempt to adjust any of
the settings. Determine the cause of