![GORMAN-RUPP 03H1-GR Installation, Operation And Maintenance Manual Download Page 21](http://html1.mh-extra.com/html/gorman-rupp/03h1-gr/03h1-gr_installation-operation-and-maintenance-manual_2246637021.webp)
0 SERIES
OM-01194
MAINTENANCE & REPAIR
PAGE E - 1
PUMP MAINTENANCE AND REPAIR ‐ SECTION E
MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK
OPERATING PERFORMANCE.
STANDARD PERFORMANCE FOR PUMP MODEL 03H1-GR
Based on 70
_
F (21
_
C) clear water corrected to
0.8 specific gravity at sea level with minimum suc
tion lift. Since pump installations are seldom identi
cal, your performance may be difference due to
such factors as viscosity, specific gravity, elevation,
temperature, and impeller trim.
If your pump serial number is followed by an “N”,
your pump is
NOT
a standard production model.
Contact the Gorman‐Rupp Company to verify per
formance or part numbers.
Pump speed and operating condition
points must be within the continuous per
formance range shown on the curve.