GORMAN-RUPP PUMPS Super T T6B60S-B Installation, Operation And Maintenance Manual Download Page 26

ITEM 
NO.

PART NAME

PART 
NUMBER

QTY

ITEM 
NO.

PART NAME

PART 
NUMBER

QTY

OM-05604

SUPER T SERIES

MAINTENANCE & REPAIR

PAGE E - 3

PARTS LIST

Pump Model T6B60S-B

,  I

ncluding /F, /FM

(From S/N 1285214 Up)

If your pump serial number is followed by an “N”, your pump is 

NOT

 a standard production model. Contact

the Gorman‐Rupp Company to verify part numbers.

1

PUMP CASING

SEE NOTE BELOW

1

2

REPAIR ROTATING ASSY

44163-401

1

3

STUD

C1213 15991

4

4

CASING DRAIN PLUG

P20 10009

1

5

WEAR PLATE

46451-717 24100

1

6

O‐RING

25152-453

1

7

LOCK WASHER

J06 15991

6

8

HEX NUT

D06 15991

4

9

O‐RING

S1676

2

10

BACK CVR PLATE ASSY

42111-822

1

 -WARNING PLATE

2613EV 13990

1

 -DRIVE SCREW

BM#04-03 17000

4

 -PRESS RELIEF VALVE

26662-005

1

 -WARNING DECAL

38816-302

1

11

ADJUSTING SCREW

31871-070 1500G

4

12

LOCK COLLAR

38115-551 15001

4

13

BACK COVER NUT

31871-073 15000

4

14

LOCK WASHER

J08 15991

8

15

HEX HD CAPSCREW

B0804-1/2 15991

4

16

HEX HD CAPSCREW

B0604 15991

2

17

COVER PLATE HANDLE

12354 13010

1

18

HEX HD CAPSCREW
T6A60S-B

B1211 15991

8

T6A60S-B /F, /FM

B1208 15991

 6

B1211 15991

2

19

LOCK WASHER

j12 15991

16

20

PIPE PLUG

P04 15079

2

   20A

PIPE PLUG

P04 15079

1

21

SUCT FLANGE

11402 10010

1

22

CHECK VALVE PIN

11645 17010

1

23

FLAP VALVE ASSY

46411-064

1

24

GASKET

11402G 19370

1

25

GASKET

25113-036

1

26

MACHINE BOLT

A1014 15991

2

27

DISCHARGE FLANGE

1758 10010

1

28

HEX HD CAPSCREW

B1208 15991

8

29

CLAMP BAR SCREW

31912-009 15000

1

30

CLAMP BAR

38111-004 11010

1

31

FILL COVER PLATE ASSY 42111-344

1

 -WARNING PLATE

38816-097 13990

1

 -DRIVE SCREW

BM#04-03 17000

2

 -COVER GASKET

50G 19210

1

32

HEX HD CAPSCREW

B0806 15991

4

33

ROT ASSY ADJ SHIM

13131-3 17040

8

34A PIPE PLUG

P08 15079

1

35

NAME PLATE

38819-002 13000

1

36

DRIVE SCREW

BM#04-03 17000

4

NOT SHOWN:

LUBE DECAL

38817-084

1

ROTATION DECAL

2613M

1

WARNING DECAL

2613FE

1

SUCTION STICKER

6588AG

1

PRIMING STICKER

6588AH

1

DISCHARGE STICKER

6588BJ

1

SUPER “T” DECAL

38812-089

1

G‐R DECAL

GR-03

1

INSTRUCTION TAG

38817-023

1

OPTIONAL:

DISASSEMBLY TOOL

48711-020

1

/F FLANGE KIT

48213-041

1

/FM METRIC FLANGE KIT

48213-078

1

CASING HEATERS:
-120V

47811-080

1

-240V

47811-081

1

CHECK VALVE ASSYS:
-NEO SOLID TYPE

46411-019

1

-VITON SOLID

46411-078

1

-VITON BLOW-OUT

46411-088

1

PRESS RELIEF VALVES:
 -SEWAGE TYPE

46431-628

1

 -STAINLESS STEEL

26662-101

1

HI TEMP SHUT-DOWN KITS:
 -145

F

48313-186

1

 -130

F

48313-256

1

 -120

F

48313-257

1

HIGH TEMP SHUT‐DOWN
THERMOSTAT KIT 145

F

48313-172

1

AIR RELEASE VALVES:
 -10# COMP SPRING

GRP33-07A

1

 -25# COMP SPRING

GRP33-07

1

 -80# COMP SPRING

GRP33-07B

1

BACK COVER O‐RINGS

-VITON

25154-454

1

 

INDICATES PARTS RECOMMENDED FOR STOCK

INCLUDED WITH REPAIR 

46472-722

1

PUMP CASING ASSY

 VITON

  IS A REGISTERED TRADEMARK OF THE DUPONT CORP.

COMPLETE GASKET/O‐RING AND SHAFT REPAIR KITS AVAILABLE - CONSULT FACTORY.

Summary of Contents for Super T T6B60S-B

Page 1: ...ril 28 2004 Rev H 08 28 17 GORMAN RUPP PUMPS www grpumps com 2004 Gorman Rupp Pumps Printed in U S A INSTALLATION OPERATION AND MAINTENANCE MANUAL WITH PARTS LIST SUPER T SERIES PUMPS MODELS T6B60S B...

Page 2: ...rial number and e mail address required RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this in...

Page 3: ...g PAGE B 4 DISCHARGE LINES PAGE B 5 Siphoning PAGE B 5 Valves PAGE B 5 Bypass Lines PAGE B 5 AUTOMATIC AIR RELEASE VALVE PAGE B 6 Air Release Valve Installation PAGE B 6 ALIGNMENT PAGE B 7 Coupled Dri...

Page 4: ...tion Check Valve Removal PAGE E 7 Rotating Assembly Removal PAGE E 7 Impeller Removal PAGE E 8 Seal Removal PAGE E 8 Shaft and Bearing Removal and Disassembly PAGE E 8 Shaft and Bearing Reassembly and...

Page 5: ...y P O Box 1217 Mansfield Ohio 44901 1217 Phone 419 755 1011 or Gorman Rupp of Canada Limited 70 Burwell Road St Thomas Ontario N5P 3R7 Phone 519 631 2870 For information or technical assistance on the...

Page 6: ...Allow the pump to completely cool if overheated 4 Check the temperature before opening any covers plates or plugs 5 Close the suction and discharge valves 6 Vent the pump slowly and cau tiously 7 Dra...

Page 7: ...entilate the area 3 Allow the pump to completely cool 4 Check the temperature before opening any covers plates gauges or plugs 5 Vent the pump slowly and cau tiously 6 Refer to instructions in this ma...

Page 8: ...n a flooded suction application where the liquid is supplied to the pump under pressure some of the information such as mounting line configuration and priming must be tailored to the specific applica...

Page 9: ...contact your Gorman Rupp distributor or the factory to deter mine the repair or updating policy Do not put the pump into service until appropriate action has been taken POSITIONING PUMP Death or serio...

Page 10: ...desired for pumps that are not tapped drill and tap the suction and discharge lines not less than 18 inches 457 2 mm from the suction and discharge ports and install the lines Installation closer to t...

Page 11: ...ion pipe The baffle will allow entrained air to escape from the liquid before it is drawn into the suction inlet If two suction lines are installed in a single sump the flow paths may interact reducin...

Page 12: ...ications less than 30 feet or 9 meters it is recommended that the by pass line be run back to the wet well and located 6 inches below the water level or cut off point of the low level pump In some ins...

Page 13: ...casing drain plug Use caution when re moving the plug to prevent injury to per sonnel from hot liquid AUTOMATIC AIR RELEASE VALVE When properly installed a Gorman Rupp Auto matic Air Release Valve wil...

Page 14: ...ys tem do not direct bleeder lines to a common mani fold pipe Contact your Gorman Rupp distributor or the Gorman Rupp Company for information about installation of an Automatic Air Release Valve for y...

Page 15: ...the same distance apart at all points see Figure 5 Figure 5 Aligning Non Spider Type Couplings Check parallel adjustment by laying a straightedge across both coupling rims at the top bottom and side W...

Page 16: ...drive belts check the tension after 5 20 and 50 hours of operation and re tension as re quired see the following procedure for measuring belt tension Thereafter check and re tension if re quired month...

Page 17: ...o service for the first time 2 The pump has not been used for a consider able length of time 3 The liquid in the pump casing has evapo rated Once the pump casing has been filled the pump will prime an...

Page 18: ...ails to prime within five minutes stop it and check the suction line for leaks After the pump has been primed partially close the discharge line throttling valve in order to fill the line slowly and g...

Page 19: ...sing pipe dope on the threads Block the suction line and start the pump At oper ating speed the pump should pull a vacuum of 20 inches 508 0 mm or more of mercury If it does not check for air leaks in...

Page 20: ...considered normal for bearings and they can operate safely to at least 180 F 82 C Checking bearing temperatures by hand is inaccu rate Bearing temperatures can be measured ac curately by placing a con...

Page 21: ...r gasket Not enough liquid in casing Add liquid to casing See PRIMING Suction check valve contaminated or damaged Clean or replace check valve Suction check valve or foot valve clogged or binding Clea...

Page 22: ...eck valve or foot valve clogged or binding Clean valve Suction lift or discharge head too high Check piping installation and install bypass line if needed See INSTAL LATION Impeller clogged or damaged...

Page 23: ...tely the same duty cycle the part can be checked and replaced before failure occurs reducing unscheduled down time For new applications a first inspection of wearing parts at 250 hours will give insig...

Page 24: ...level with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature and impeller tr...

Page 25: ...OM 05604 SUPER T SERIES MAINTENANCE REPAIR PAGE E 2 ILLUSTRATION PARTSPAGE Figure 1 Pump Model T6B60S B Including F FM...

Page 26: ...6 MACHINE BOLT A1014 15991 2 27 DISCHARGE FLANGE 1758 10010 1 28 HEX HD CAPSCREW B1208 15991 8 29 CLAMP BAR SCREW 31912 009 15000 1 30 CLAMP BAR 38111 004 11010 1 31 FILL COVER PLATE ASSY 42111 344 1...

Page 27: ...OM 05604 SUPER T SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION ASSEMBLED DRIVE END VIEW Figure 2 Repair Rotating Assembly...

Page 28: ...IR VENT S1530 1 14 PIPE PLUG P12 15079 1 15A SIGHT GAUGE S1471 1 15B SIGHT GAUGE S1471 1 16A BRG CAVITY DRAIN PLUG P04 15079 1 16B BRG CAVITY DRAIN PLUG P04 15079 1 17 HEX HD CAPSCREW B0605 15991 4 18...

Page 29: ...wing instructions assume complete disassem bly is required Before attempting to service the pump disconnect or lock out the power source and take precautions to ensure that it will remain inoperative...

Page 30: ...ssembly Removal Figure 2 The rotating assembly may be serviced without disconnecting the suction or discharge piping however the power source must be removed to provide clearance The impeller 1 should...

Page 31: ...aft sleeve and rotating portion of the seal off the shaft as a unit Use a pair of stiff wires with hooked ends to remove the stationary element and seat An alternate method of removing the stationary...

Page 32: ...snug slip fit into the bearing housing Replace the bearings shaft or bearing housing if the proper bearing fit is not achieved If bearing replacement is required remove the out board bearing snap ring...

Page 33: ...n the shaft with the bearing snap ring 21 Slide the shaft and assembled bearings into the bearing housing until the retaining ring on the out board bearing seats against the bearing housing When insta...

Page 34: ...mall amount of light lubricating oil See Figure 5 for seal part identification SEAL PLATE O RINGS IMPELLER OIL SEAL STATIONARY STATIONARY ROTATING DRIVE BAND BELLOWS IMPELLER SHIMS IMPELLER SPRING RET...

Page 35: ...adjusting shims to obtain the proper clearance as described in Impeller Instal lation and Adjustment If necessary to reuse an old seal in an emer gency carefully separate the rotating and station ary...

Page 36: ...check the threads for dirt Do not try to force the impeller onto the shaft A clearance of 025 to 040 inch 0 64 to 1 02 mm between the impeller and the seal plate is recom mended for maximum pump effic...

Page 37: ...the impeller when the shaft is turned by hand Tighten the hand nuts evenly to avoid binding With the wear plate just touching the impeller turn the two free adjusting screws until they engage the pum...

Page 38: ...assembly 31 and fill the pump casing with clean liquid Reinstall the fill cover and tighten it Refer to OPERATION Section C before putting the pump back into service LUBRICATION Seal Assembly Figure 2...

Page 39: ...For Warranty Information Please Visit www grpumps com warranty or call U S 419 755 1280 Canada 519 631 2870 International 1 419 755 1352 GORMAN RUPP PUMPS...

Reviews: