![GORMAN-RUPP PUMPS Super T T4A60S-4LET2T FT4-ESP Series Installation, Operation, And Maintenance Manual With Parts List Download Page 13](http://html1.mh-extra.com/html/gorman-rupp-pumps/super-t-t4a60s-4let2t-ft4-esp-series/super-t-t4a60s-4let2t-ft4-esp-series_installation-operation-and-maintenance-manual-with-parts-list_2246932013.webp)
OM-07116
SUPER T SERIES
PAGE B - 6
INSTALLATION
a. Handle the signal cable and transducer with
care during installation.
Carefully
lower the
transducer into the wet well or sump;
do not
drop it to the bottom. To avoid clogging, sus
pend the transducer off the bottom.
b.
Be sure
to provide sufficient room in the wet
well or sump so that the transducer does not
get drawn into the suction line. To prevent this,
a flexible suction hose may be extended to lay
along the bottom of the wet well or sump. The
transducer can then be attached to the hose
above the point where it bends along the bot
tom. See Figure B-4 for a typical installation.
c. The wet well or sump must be vented to atmo
sphere.
d. The EPS is scaled in feet of water column. If
the measured medium is other than 1.0 spe
cific gravity, the reading on the EPS should be
divided by the specific gravity of the mea
sured medium to obtain the actual level.
e.
Thoroughly
clean the transducer after each
use to prevent clogging.
Do not
disassemble the transducer or
loosen the compression nut at the signal
cable entry.
This will void warranty.
There
are no user‐serviceable parts inside. Do
not nick or cut the jacket of the signal
cable; this will cause leakage and
void
warranty
.
FLOW
DISCHARGE
LINE
SUCTION
LINE
SIGNAL CABLE
(ATTACH TO
SUCTION LINE)
SUBMERSIBLE
TRANSDUCER
(DOWNSTREAM
FROM SUCTION)
SUCTION
STRAINER
Figure 4. Typical Submersible Transducer Installation