![GORMAN-RUPP PUMPS S8B1-E100 460/3 Installation, Operation And Maintenance Manual Download Page 48](http://html1.mh-extra.com/html/gorman-rupp-pumps/s8b1-e100-460-3/s8b1-e100-460-3_installation-operation-and-maintenance-manual_2246921048.webp)
OM-06259
S SERIES PUMPS
PAGE E - 23
MAINTENANCE AND REPAIR
To fill the seal cavity, remove the pipe plug (11) and
add the recommended grade of submersible
pump oil. Apply `Loctite Pipe Sealant With Teflon
No. 592' or equivalent to the threads of the pipe
plug, before reinstalling the plug.
See Table E-2 for quantity of lubricant when lubri
cating a dry (overhauled) pump. See Table E-3 for
lubricant specifications.
The grade of lubricant used is critical to the opera
tion of this pump. Use premium quality hydraulic oil
as specified in Table E-3. Oil must be stored in a
clean, tightly closed container in a reasonably dry
environment.
Table E-2. Oil Quantity
Pump Model
Seal Cavity
Motor Cavity
S8B1
768 ounces (22,7 liters)
224 ounces (6,6 liters)
Table E-3. Pump Oil Specifications
Specifications:
Type
Premium high viscosity index, anti‐wear hydraulic oil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viscosity (SSU @ 104
F [40
C])
110 to 155
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dielectric
26,000 (volts‐min)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Acceptable alternate suppliers:
Gulf Oil Company
Gulf Harmony AW Hydraulic Fluid MG 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Texas Oil Company
Rando HD 32 or HD AZ 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sun Oil Company
Sunvis 816 or 916
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BP (Also Boron)
Energol‐HLP 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shell Oil Company
Tellus 32, Tellus T‐23 or T32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viscosity (SSU @ 210
F [100
C])
40 to 50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended supplier:
Gulf Oil Company
Gulf Harmony 32 AW
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ARCO
Duro 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exxon (Also Esso)
Nuto H 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Petro‐Canada
Harmony HVI 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor Housing Cavity
With the pump in an upright position, remove the
pipe cap (27) on the top of the pump. See Table
E-2 and add the recommended quantity of lubri
cant to the motor cavity.
Maintain the oil at this
level
. Apply `Loctite Pipe Sealant With Teflon No.
592' or equivalent sealant to the threads of the
street tee assembly (28). Reinstall and tighten the
cap.
Never attempt to fill the motor cavity
through the drain plug (10) opening. A vol
ume of air must be trapped above the mo
tor to permit thermal expansion of the mo
tor oil.