GORMAN-RUPP PUMPS S8B1-E100 460/3 Installation, Operation And Maintenance Manual Download Page 11

 

OM-06259

S SERIES PUMPS

PAGE B - 4

INSTALLATION

ting near the pump. The discharge line must be in­
dependently supported to avoid strain and vibra­
tion on the pump.

Either hose or rigid pipe may be used to make dis­
charge connections. For maximum pumping ca­
pacity, keep the line as short and straight as pos­
sible. Elbows and fittings used in discharge lines
increase friction loss, minimize their use.

It is recommended that a check valve or throttling
valve be installed in the discharge line to control si­
phoning or back flow when the pump is shut off.

ELECTRICAL CONNECTIONS

Install and operate this pump in accor­
dance with the National Electrical Code
and all local codes. Have a qualified
electrician perform all checks and con­
nections in this section.
Never attempt to alter the length of the
pump motor cable or to repair it with a
splice. The power cable and pump mo­
tor must be kept completely waterproof.
Serious damage to the pump and injury
or death to personnel can result from
any alteration to the cable.

Control Box Installation

The pump is designed to be operated
through the control box furnished with
the pump. The control box provides
overload protection and power control.
Do not connect the pump motor directly
to the incoming power lines.

The control box is a rainproof enclosure with a pad­
lockable front cover. 

The enclosure is not de­

signed to be watertight, and should not be sub­
merged.

 Refer to the control box manual for enclo­

sure dimensions and parts.

Secure the control vertically on a level surface,
above flood level. The box should be easily acces­

sible to the operator, and located close enough to
the pump to avoid excessive voltage drop due to
cable length (see 

Pump Power Cable Connec­

tion

). After the box is installed, make certain the

front cover latches properly.

Failure to mount the control box vertically
on a level surface may affect operation of
the pump controls.

Field Wiring Connections (Incoming Power)

The electrical power used to operate
this pump is high enough to cause inju­
ry or death. Obtain the services of a
qualified electrician to make all electri­
cal connections. Make certain that the
pump and enclosure are properly
grounded; never use gas pipe as an
electrical ground. Be sure that the in­
coming power matches the voltage and
phase of the pump and control before
connecting the power source. Do not
run the pump if the voltage is not within
the limits.

Do not connect the pump motor directly
to the incoming power lines. The pump
motor is designed to operate through a
Gorman‐Rupp approved control box
which provides overload protection and
power control; otherwise, the pump
warranty will be voided. Make certain
that the pump and control box are prop­
erly grounded. Install and operate the
control box in accordance with the Na­
tional Electric Code and all local codes.
Failure to follow these could result in in­
jury or death to personnel.

Field wiring is 

not

 provided with the pump, and

must be supplied by the user. The field wiring must

Summary of Contents for S8B1-E100 460/3

Page 1: ...June 16 2022 GORMAN RUPP PUMPS www grpumps com 2022 Gorman Rupp Pumps Printed in U S A INSTALLATION OPERATION AND MAINTENANCE MANUAL WITH PARTS LIST SUBMERSIBLE PUMPS MODELS S8B1 E100 460 3 and S8B1...

Page 2: ...rial number and e mail address required RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this in...

Page 3: ...able Grounding Test PAGE B 7 Control Box Connections PAGE B 7 Liquid Level Devices PAGE B 7 WIRING DIAGRAMS PAGE B 8 OPERATION SECTION C PAGE C 1 GENERAL INFORMATION PAGE C 1 Pump Performance PAGE C 1...

Page 4: ...and Strainer Plate Installation PAGE E 11 Strainer Screen and Base Plate Installation PAGE E 12 MOTOR DISASSEMBLY PAGE E 12 Terminal Housing and Power Cable Removal and Disassembly PAGE E 12 Intermed...

Page 5: ...y P O Box 1217 Mansfield Ohio 44901 1217 Phone 419 755 1011 or Gorman Rupp of Canada Limited 70 Burwell Road St Thomas Ontario N5P 3R7 Phone 519 631 2870 For information or technical assistance on the...

Page 6: ...pump or endan ger personnel as a result of pump fail ure Consult the factory for specific ap plication data Before connecting any cable to the con trol box be sure to ground the control box Refer to...

Page 7: ...led make certain that the pump and all piping or hose connections are secure before op eration Obtain the services of a qualified elec trician to troubleshoot test and or ser vice the electrical compo...

Page 8: ...d hertz indicated on the name plate match the ratings on the control box and incoming pow er e Carefully read all tags decals and markings on the pump and perform all duties indicated f Check for oil...

Page 9: ...age Phase 460 3 575 3 S8B Approximate Weight Lbs kg Oil Capacity Ounces Liters Seal Cavity Filling Position H orizontal V ertical Pump 50 Ft Cable Seal Cavity Motor Cavity 870 395 105 48 224 6 6 768 2...

Page 10: ...olves a lot of debris protect the pump from excessive wear and clogging by sus pending it in a perforated barrel or culvert pipe If the bottom is heavily sludge covered rest the pump on support blocks...

Page 11: ...be sub merged Refer to the control box manual for enclo sure dimensions and parts Secure the control vertically on a level surface above flood level The box should be easily acces sible to the operat...

Page 12: ...on cable clamps and cable Grounding Methods Electrically ground the installation before connect ing the field wiring to the control box Install a grounding terminal to the enclosure and connect it to...

Page 13: ...ed out or that the power supply to the control box has been otherwise cut off and locked out before connecting power or accessory cables The pump is provided with a 50 ft 15 2 m power cable see Table...

Page 14: ...tion through an approved control box Ground and wire the control box in accordance with the instructions accompanying it NOTE For reference internal motor wiring connections are shown in Maintenance a...

Page 15: ...BOX LIQUID LEVEL RANGE OFF DEWATERING ON FILLING DIAPHRAGM TYPE Figure B 4 Liquid Level Devices The internal wiring of the sensing devices are different for filling and dewatering func tions Be sure...

Page 16: ...automatic liquid level sensing device in which case those circuits are also contained within the control box The pump motor and control box are not designed to be explosion proof Do not operate in an...

Page 17: ...pump immediately 2 Ventilate the area 3 Allow the pump to completely cool 4 Check the temperature before ser vicing 5 Vent the pump slowly and cau tiously 6 Refer to instructions in this manual befor...

Page 18: ...the integral thermal over load device will shut off the motor if the temperature rises above design limits When the pump cools and the tempera ture falls below these limits the motor will restart auto...

Page 19: ...the oil level s as indicated in the following LUBRICATION section COLD WEATHER PRESERVATION Do not attempt to thaw the pump by us ing a torch or other source of flame This could damage gaskets O ring...

Page 20: ...ding Oil Refer to Table B 2 in INSTALLATION for oil ca pacities and positions for filling the seal cavity in your pump Motor cavities requiring lubrication should always be positioned vertically for f...

Page 21: ...26 000 volts min Acceptable alternate suppliers Gulf Oil Company Gulf Harmony HVI AW 26 Texas Oil Company Rando HD 32 or HD AZ 32 Sun Oil Company Sunvis 816 or 916 BP Also Boron Energol HLP 32 Shell O...

Page 22: ...sing device s Float type sensing device s tangled or obstructed Check installation for free movement of float Defective liquid level sensing de vice s or control panel Repair or replace defective unit...

Page 23: ...or tank Stop pump until liquid level rises Worn impeller vanes excessive im peller clearance Check impeller and clearance see PUMP END REASSEMBLY in Maintenance and Repair Section E Pump running back...

Page 24: ...under each condition must be the same b If voltage is balanced when the pump is off but is imbalanced when the pump is running thoroughly check the power source all inter connecting cables and the pum...

Page 25: ...le and motor windings If resistance reads infinity 1 insulation is good If resistance reads between infinity 1 and 1 megohm insulation is acceptable but should be rechecked regularly If resistance rea...

Page 26: ...water at sea level with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature an...

Page 27: ...S SERIES PUMPS OM 06259 MAINTENANCE AND REPAIR PAGE E 2 SECTION DRAWING PARTSPAGE Figure E 1 S8B1 E100 460 3 And S8B1 E100 575 3 Pump Assemblies...

Page 28: ...LANGE STUD C1211 15991 8 33 HEX NUT D12 15991 8 34 FILL TUBE ASSY 10040 24040 1 35 RETAINING RING S245 1 36 TERM HSG CABLE ASSY 460 3 47367 061 1 575 3 47367 028 1 37 STUD C0607 15991 6 38 DEFORM LOCK...

Page 29: ...S SERIES PUMPS OM 06259 MAINTENANCE AND REPAIR PAGE E 4 SECTION DRAWING Figure E 2 Terminal Housing And Cable Assembly...

Page 30: ...31133 110 15991 1 8 GLAND BUSHING 460 3 10758E 19100 1 575 3 31144 001 19100 1 9 INFORMATION PLATE 38816 047 17990 1 10 DRIVE SCREW BM 04 03 17000 4 11 CABLE GRIP 460 3 11227F 1 575 3 11227H 1 12 TERM...

Page 31: ...ect a flexible discharge hose before removing the pump If rigid discharge piping is used disconnect the piping before attempting to move the pump Do not attempt to lift the pump by the motor power cab...

Page 32: ...rity of the motor cavity probably due to poor gaskets or seals Positioning Pump For Disassembly Figure E 1 It is recommended that the pump be positioned upside down during disassembly To hold the pump...

Page 33: ...press on alternate sides of the stationary seat until the stationary seat and O rings are removed Inspect the wear ring 65 for excessive wear or scoring and replace as required The wear ring is a pres...

Page 34: ...mable Use them only in a well ven tilated area free from excessive heat sparks and flame Read and follow all precautions printed on solvent contain ers Inspect the rotor shaft 39 for damaged threads s...

Page 35: ...ust be replaced as an assembly Apply a light coating of oil to the bore of the intermediate Carefully remove the material stuffed into the seat bore or unwrap the shaft Be sure no debris stopped by th...

Page 36: ...he of the seal seat Keep the sealing face dry Position this subassembly in the seal plate bore with the sealing face up and cover it with a clean tissue Use your thumbs to press the seat into the bore...

Page 37: ...sive wear will result Install the suction head gasket 6 over the studs 58 and carefully position the suction head over the studs Coat the studs with Never Seez or equivalent compound Install the lockw...

Page 38: ...e cable Quite of ten pressure exerted on the bushing will deform the cable jacket If such happens additional oil and effort will be required to remove the bushing NOTE If the rubber bushing cannot be...

Page 39: ...bearings from the rotor shaft clean and inspect the bearings in place as follows Clean the bearings thoroughly in fresh cleaning solvent Dry the bearings with filtered compressed air and coat with li...

Page 40: ...ite Retaining Com pound No 680 or No 620 or equivalent com pound on both ends of the nipple only When installing the relief valve use Loctite Pipe Sealant With Teflon No 592 or equivalent com pound on...

Page 41: ...or is clear to avoid a fire hazard or damage to the wind ings Apply heat evenly to the outside of the hous ing excessive heat is not required When the motor housing is sufficiently heated po sition th...

Page 42: ...SEALS OR SHIELDS WHEN INSTALLED ON THE SHAFT THE MAN UFACTURER S PART NUMBER DESCRIPTION LOCATED ON SIDE FACE OF BEARING OR BEARING O D MUST BE LOCATED WITH THE TEXT AWAY FROM THE IMPELLER Figure E 4...

Page 43: ...e threads of the motor housing studs 44 Secure the intermediate to the motor housing with the hardware 45 and 46 torque the nuts evenly in a cross sequence to 120 ft lbs 1440 in lbs or 16 6 m kg Refer...

Page 44: ...required If the rubber bonding material on the terminal plate 19 is severely worn or cracked the terminal plate must be replaced If the bonding ma terial has been noticeably compressed it should be s...

Page 45: ...s 1 potting compound Chemseal potting compound part number GS3100 or equiv alent may also be used to seal the connections Clean and assemble all terminal components as indicated in Sealing Terminal Pl...

Page 46: ...ch terminal post 1 using the allen head set screws 21 Position the terminal housing and terminal plate against the upper motor housing If required ro tate the terminal housing and twist the motor lead...

Page 47: ...Closing Ball Type Shutoff Valve Quick Disconnect Fitting Quick Disconnect Fitting Air Compressor Venturi Figure E 7 Vacuum Test System Table E 1 shows the vacuum to be drawn on each cavity and the dur...

Page 48: ...anti wear hydraulic oil Viscosity SSU 104 F 40 C 110 to 155 Dielectric 26 000 volts min Acceptable alternate suppliers Gulf Oil Company Gulf Harmony AW Hydraulic Fluid MG 32 Texas Oil Company Rando HD...

Page 49: ...For Warranty Information Please Visit www grpumps com warranty or call U S 419 755 1280 Canada 519 631 2870 International 1 419 755 1352 GORMAN RUPP PUMPS...

Reviews: