GORMAN-RUPP PUMPS 16A2-F3L Installation, Operation, And Maintenance Manual With Parts List Download Page 5

10 SERIES

OM−00698

PAGE I − 1

INTRODUCTION

INTRODUCTION

Thank You

 for purchasing a Gorman-Rupp pump.

Read this manual 

carefully to learn how to safely

install and operate your pump. Failure to do so
could result in personal injury or damage to the
pump.

This Installation, Operation, and Maintenance
manual is designed to help  you achieve the best
performance and longest life from your Gorman-
Rupp pump.

This pump is a 10 Series, semi-open impeller, self-
priming centrifugal model with a suction check
valve. The pump is powered by a Deutz Diesel en-
gine. The pump is designed for handling dirty
water containing specified entrained solids. The
basic material of construction for wetted parts is
gray iron, with ductile iron impeller and steel wear-
ing parts.

If  there are any questions regarding the pump or
its application which  are not covered in this man-
ual or in other literature accompanying this unit,
please contact your Gorman-Rupp distributor, or
write:

The Gorman-Rupp Company

P.O. Box 1217

Mansfield, Ohio  44901−1217

Phone: (419) 755−1011

or:

Gorman-Rupp of Canada Limited

70 Burwell Road

St. Thomas, Ontario N5P 3R7

Phone: (519) 631−2870

For information or technical assistance on the en-
gine, contact the engine manufacturer’s local
dealer or representative.

Because pump installations are seldom identical,
this manual cannot possibly provide detailed in-
structions and precautions for every aspect of
each specific application. Therefore, it is the re-
sponsibility of the owner/installer of the pump to
ensure that applications not addressed in this
manual are performed 

only

 after establishing that

neither operator safety nor pump integrity are com-
promised by the installation. Pumps and related
equipment 

must

 be installed and operated ac-

cording to all national, local and industry stan-
dards.

The following are used to alert maintenance per-
sonnel  to procedures which  require special atten-
tion, to those which could damage equipment, and
to those which could be dangerous to personnel:

Immediate hazards which WILL result in
severe personal injury or death. These
instructions describe the procedure re-
quired and the injury which will result
from failure to follow the procedure.

Hazards or unsafe practices which
COULD result in severe personal injury
or death. These instructions describe
the procedure required and the injury
which could result from failure to follow
the procedure.

Hazards or unsafe practices which COULD
result in minor personal injury or product
or property damage. These instructions
describe the requirements and the possi-
ble damage which could result from failure
to follow the procedure.

NOTE

Instructions to aid in installation, operation,and
maintenance, or which clarify a procedure.

Summary of Contents for 16A2-F3L

Page 1: ...THE GORMAN RUPP COMPANY MANSFIELD OHIO GORMAN RUPP OF CANADA LIMITED ST THOMAS ONTARIO CANADA Printed in U S A www grpumps com 2005 The Gorman Rupp Company INSTALLATION OPERATION AND MAINTENANCE MANUA...

Page 2: ...NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this information when you require parts or service Pump Model Serial Number The...

Page 3: ...ing PAGE B 4 Suction Lines In Sumps PAGE B 4 Suction Line Positioning PAGE B 4 FLOAT SWITCHES PAGE B 5 Installation PAGE B 5 DISCHARGE LINES PAGE B 6 Siphoning PAGE B 6 Valves PAGE B 6 Bypass Lines PA...

Page 4: ...er Removal PAGE E 7 Suction Check Valve Removal PAGE E 7 Separating Pump and Intermediate from Engine PAGE E 8 Loosening the Impeller PAGE E 8 Pump Casing Removal PAGE E 9 Impeller Removal PAGE E 9 Se...

Page 5: ...cause pump installations are seldom identical this manual cannot possibly provide detailed in structions and precautions for every aspect of each specific application Therefore it is the re sponsibili...

Page 6: ...pump If the pump is equipped with the option al automatic starting system it is sub ject to automatic restart Keep hands and clothing away from the unit to pre vent injury during automatic operation D...

Page 7: ...se fumes contain carbon monoxide a deadly gas that is color less tasteless and odorless Pumps and related equipment must be in stalled and operated according to all na tional local and industry standa...

Page 8: ...p under pressure some of the information such as mounting line configuration and priming must be tailored to the specific application Since the pressure supplied to the pump is critical to performance...

Page 9: ...Table 1 Battery Specifications 20 5L x 12 Volts 960 975 365 175 8 75W x 9 75H Voltage Cold Reserve Approx Crank Capacity Amp Overall Amps 80 F Hr Dims 0 F Minutes Rating Inches Refer to the informati...

Page 10: ...p ported to avoid strain on the pump which could cause excessive vibration decreased bearing life and increased shaft and seal wear If hose type lines are used they should have adequate support to sec...

Page 11: ...ffle between the inflow and the suction inlet at a distance 1 1 2 times the diameter of the suction pipe The baffle will allow entrained air to escape from the liquid before it is drawn into the sucti...

Page 12: ...above the point where it bends along the bot tom Direct the suction line toward the flow and the float s away from the flow If a stand pipe is available attach the float switch cable to the standpipe...

Page 13: ...minimize the chance of plugging In low discharge head applications less than 30 feet 9 1 m it is recommended that the bypass line be run back to the wet well and located 6 inches below the water level...

Page 14: ...ng description of operation During the priming cycle air from the pump casing flows through the bypass line and passes through the Air Release Valve to the wet well Figure 4 When the pump is fully pri...

Page 15: ...The valve inlet is at the large end of the valve body and is provided with standard 1 inch NPT pipe threads The valve outlet is located at the opposite end of the valve and is also equipped with stan...

Page 16: ...properly lubri cated see LUBRICATION in MAINTENANCE AND REPAIR This pump is self priming but the pump should never be operated unless there is liquid in the pump casing Never operate this pump unless...

Page 17: ...ntil the red AUTO light illuminates The auto start system is now armed NOTE The unit can continue to be started manually with the keyswitch in the AUTO START position by pressing the white MAN button...

Page 18: ...gs Keep all line connections and fittings tight to maintain maxi mum pump efficiency Liquid Temperature And Overheating The maximum liquid temperature for this pump is 110 F 43 C Do not apply it at a...

Page 19: ...In the automatic mode the pump will stop when the liquid in the wet well or sump lowers and acti vates the Off float switch s The pump will restart automatically when the liquid rises and activates th...

Page 20: ...is inaccu rate Bearing temperatures can be measured ac curately by placing a contact type thermometer against the housing Record this temperature for future reference A sudden increase in bearing temp...

Page 21: ...do so may result in serious personal injury TROUBLE POSSIBLE CAUSE PROBABLE REMEDY PUMP FAILS TO PRIME Not enough liquid in casing Suction check valve contaminated or damaged Air leak in suction line...

Page 22: ...ow Liquid solution too thick Discharge line clogged or re stricted hose kinked Suction check valve or foot valve clogged or binding Open discharge valve fully to in crease flow rate and run engine at...

Page 23: ...ly the same duty cycle the part can be checked and replaced before failure occurs reducing unscheduled down time For new applications a first inspection of wearing parts at 250 hours will give insight...

Page 24: ...with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature and impeller trim If...

Page 25: ...10 SERIES OM 00698 MAINTENANCE REPAIR PAGE E 2 SECTION DRAWING PARTSPAGE Figure 1 Pump Model 16A2 F3L...

Page 26: ...TERY BOX ASSY 42431 030 24150 1 24 FLANGED HEX NUT 21765 314 8 25 T TYPE LOCKWASHER BL06 15991 1 26 STUD MOUNT 24631 006 4 27 HEX HD CAPSCREW B0604 15991 10 28 FLAT WASHER K06 15991 10 29 FLANGED HEX...

Page 27: ...10 SERIES OM 00698 MAINTENANCE REPAIR PAGE E 4 SECTION DRAWING DRIVE END VIEW Figure 2 16A2 SAE 4 10 Pump End Assy...

Page 28: ...1 38 SEAL LINER 7408 14010 REF 39 PIPE NIPPLE T12 15079 1 40 PIPE COUPLING AE12 15079 1 41 SIGHT GAUGE S1471 1 42 INTERMEDIATE GUARD 42381 031 24152 1 43 INTERMEDIATE GUARD 42381 032 24152 1 44 IMPELL...

Page 29: ...SAE 4 10 Drive Assembly PARTS LIST ITEM NO PART NAME PART NUMBER MAT L CODE QTY 1 COUPLING KIT 48112 001 1 2 BUSHING 24131 345 1 3 COUPLING ASSEMBLY 44165 011 1 4 LOCKWASHER 21171 536 8 5 SOCKET HD C...

Page 30: ...o ensure that the pump will remain inop erative Close all valves in the suction and dis charge lines For engine disassembly and repair consult the lit erature supplied with the engine or contact your...

Page 31: ...rom the bushing 2 Screw one of the setscrews into the puller hole on the circumference of the bushing As the coupling and bushing separate remove the bushing and slide the coupling off the shaft Remov...

Page 32: ...29 and 30 Slide the seal plate and seal parts off the shaft as a single unit Be careful not to drop or damage any seal parts Carefully remove the stationary and rotating seal elements packing rings se...

Page 33: ...vide a tight press fit onto the shaft and a snug slip fit into the intermedi ate Replace the bearings shaft or intermediate if the proper bearing fit is not achieved If bearing replacement is required...

Page 34: ...bore until the inboard bearing is fully seated against the bore shoulder Be careful not to damage the lip of the oil seal 50 on the shaft threads When installing the shaft and bearings into the bearin...

Page 35: ...substance which may soften or otherwise dam age the rubber Install the intermediate guards 42 and 43 Figure 2 and secure the intermediate to the engine bell housing with the previously removed hardwa...

Page 36: ...the seal assembly Be careful to center the drill in the threaded grease pipe hole and not damage the threads Deburr the hole from the inside of the seal liner after drilling Slide the seal plate onto...

Page 37: ...et until the impeller scrapes against the wear plate when the shaft is turned After the impeller scrapes add approximately 010 inch 0 25 mm of gaskets NOTE An alternate method of adjusting this cleara...

Page 38: ...ll cover plate and gasket 16 and tighten the cover Refer to OPERATION Section C and start the pump LUBRICATION Seal Assembly Figure 2 Fill the grease cup 27 through the grease fitting with No 2 lithiu...

Page 39: ...f the pump is operated continuously or in stalled in an environment with rapid temperature change Monitor the condition of the bearing lubri cant regularly for evidence of rust or mois ture condensati...

Page 40: ...grpumps com warranty or call U S 419 755 1280 International 1 419 755 1352 For Canadian Warranty Information Please Visit www grcanada com warranty or call 519 631 2870 THE GORMAN RUPP COMPANY MANSFI...

Reviews: