92
MDE-LEDInetworkITS-server-4078V1.3
4.
WEB INTERfaCE
4.2.3. State setup
The standard state of the product is displayed :
►
State :
Current state of the product (Free running, tracking…)
►
Synchronization :
Current state of the synchronization
(Input 1 is waiting, Input 1 is synchronizing...)
4.2.4. NTP Setup
When you click the
NTP
button, the configuration of the NTP server software is dis
-
played.
DESCRIPTION
Here is the short description of the different fields:
►
STRATUM level
the stratum value to be stored in the NTP messages sends to the NTP clients.
►
Reference ID
A 4 letters identifier that gives information about the time refe
-
rence. This value is put in the appropriate field in the NTP frame
►
When not synchronized
Define the effect on some NTP fields when the device is not synchronized
7
. The
possible values are
LI&STRATUM unchanged
,
STRATUM=0,LI unchanged
,
STRATUM unchanged, LI=3(11b)
,
STRATUM=0, LI=3(11b)
The LEDI Network ITS can be synchronized on up to three NTP servers. In fact, the
NTP software uses only one server at the same time but can commute to another ser-
ver when there is no or not enough reply.
The NTP configuration panel shows what is the synchronization mode used by the
server or selected by the NTP software. It also shows the servers defined by the user
or detected by the software
7/ Time code is not present (server is autonomous) or the received time-code indicates that external synchronization
is lost
Summary of Contents for LEDI NETWORK DCLS
Page 42: ...42 MDE LEDInetworkITS server 4078V1 3 2 AFNOR IRIG B NFS87500 2 1 Format de la trame ...
Page 63: ...63 MDE LEDInetworkITS server 4078V1 3 NOTES FRANCAIS ...
Page 65: ...65 MDE LEDInetworkITS server 4078V1 3 USER GUIDE LEDI Network its LEDI Network server ENGLISH ...
Page 106: ...106 MDE LEDInetworkITS server 4078V1 3 2 AFNOR IRIG B NFS87500 2 1 Frame format ...
Page 127: ...127 MDE LEDInetworkITS server 4078V1 3 NOTES ...