Instructions for Use
14
Vent pipe can be bought in any technical store
(identification code PIPE SP-377628).
B - Condenser - type Dryer
Do not install the condenser dryer into the room
where a danger of freezing can occur. Freezing
of water in the condensed water drawer and the
pump can damage the appliance.
Positioning
This dryer is a self standing appliance and can
stand alone, or it can be placed either together
with a washing machine or in the kitchen as a
kitchen unit.
If the floor is uneven, use the adjustable feet to
level the machine.
3
3a
Undo the nuts. Rotate the feet to level the
machine (fig. 3).
Lock the nuts (fig. 3a).
x
Do not remove the adjustable feet. The
machine must be placed horizontally.
x
Some models of tumble dryers are supplied
with vacuum leg braces, enabling the appliance
to be placed on top of a washing machine,
without hazard of falling or tripping during the
operation of either appliance.
x
Do not put the dryer on the thicker rug thus
preventing the possibility of air circulation.
Moist Air Outlet
A – Vent dryer
There are two openings for venting out humid air,
which are situated at the bottom left-hand rear
side part of the dryer. Depending on the position
of the machine, please, close down one of the
openings with the front cover, which has already
been fastened on it, or attached to the drum (Fig
4).
Fix the cover by inserting a coin into the slash
turning it clockwise. It can be removed by turning
in the opposite direction.
If during the drying cycle the airing is not good
enough, the air-vent tube can be inserted
(screwed) into the hole. The distance between
the dryer and venting opening (airduct or window)
must not exceed two meters, otherwise
condense can accumulate in the tube, (Fig 5,6).
1 Decorative cap
2 Vent pipe
B – Condenser - type Dryer
Humidity from the laundry in the condenser dryer
is extracted into the air cooler and accumulated in
the drainage container or conducted directly into
the moist air outlet. After every drying the
condensed water drawer should be emptied, of
which you are reminded by the control lamp
which is on when the container is full. The air
cooler should be cleaned in time (see the chapter
Maintenance and Cleaning)
Channelling the condenser tube to the drain
outlet
Take off the condensed water drawer tube from
the rear side of the dryer and by fitting an elbow
on it channel the tube into the drain outlet. Height
of the drain must not exceed 800 mm.
Connecting to Power Supply
The appliance is connected to the power supply
by means of a cable cord plug. The wall socket
should be earthed (safety socket). Required
nominal current and frequency are stated on the
rating plate. The wiring should withstand
maximum load. Electric connection and earthing
should be carried out in accordance with current
standards and regulations.
IMPORTANT
In the
supply cord
is damaged, it must be
replaced by the manufacturer or his service agent
or a qualified person in order to avoid hazard.
x
The appliance should be placed in the position,
where the plug is within reach.
4
5