9
EN
If the user lowers the set temperature during the operation of the anti-legionella
functions, the function is interrupted and a new 30-day countdown begins.
Error indication
In case of an error or warning on the heater, red and green light start blinking to
indicate an error according to the table below.
When the water heater is not in use for a longer period of time and is switched off or
disconnected from the power supply, it must be emptied in case of danger of
freezing. Water from the heater is drained through the inlet pipe of the heater. For this
purpose, a special fitting (T-fitting) must be mounted between the relief valve and the
heater inlet pipe, or a discharge tap. The heater can be discharged directly through
the relief valve, by rotating the handle or the rotating valve cap to the same position
as for checking the operation. Before discharge, make sure the heater is
disconnected from the power supply, and open the hot water on the connected mixer
tap. After discharging through the inlet pipe, there is still some water left in the water
heater. The remaining water will be discharged after removing the heating flange,
through the heating flange opening.
The external parts of the water heater can be cleaned with a mild detergent solution.
Do not use solvents and abrasives.
Regular preventive maintenance inspections ensure faultless performance and long
life of your heater. The first of these inspections should be carried out by the
authorised maintenance service provider about two years from installation in order to
inspect the wear of the protective anticorrosion anode and remove the lime coating
STATUS
RED light
GREEN light
Normal operation
Heater switched off
/
/
Heater switched on, no error, heater not
operating
/
/
Heater switched on, no error, heater
operating
GLOWING
/
Operation in ECO
S
mode
Heater switched on, no error, heater not
operating
/
GLOWING
Heater switched on, no error, heater
operating
GLOWING
GLOWING
ERRORS (Call the service)
Heater switched on, temp. sensor error
(sensor 1 or sensor 2 in short circuit or open
circuit, temp. difference error)
BLINKING
BLINKING
Heater switched on, heater warning
BLINKING
BLINKING
Summary of Contents for TGR 100 SM
Page 1: ...TGR 30 120 SM...
Page 19: ...19 MK 8 0 6 6 0 9 9 1 0 MPa 10 0 1 1...
Page 20: ...20 MK 130 C TGR ECOS...
Page 22: ...22 MK 0 1 1 3 1 2 3 4 5 6 7 8 H T...
Page 23: ...23 MK 1 5 2 H05VV F 3G 1 5 2 2 1 2 3 L N...
Page 24: ...24 MK ECOS 0 ECOS 10 C 35 C ECO 55 C 75 C ECOS ECOS...
Page 26: ...26 MK 36 ECOS 1 2...
Page 44: ...10 2016 390735...