UPUTSTVO ZA UPOTREBU

 

INSTRUCTIONS FOR USE

 

SR/

M

NE

 

EN

 

 

TCM 200 

-

 300

 

 
 
 

 

 
 

 

 
 
 
 
 
 

www.gorenje.com

 

Summary of Contents for TCM200ZG

Page 1: ...UPUTSTVO ZA UPOTREBU INSTRUCTIONS FOR USE SR MNE EN TCM 200 300 www gorenje com ...

Page 2: ...eru prema dole i u području gdje nema smrzavanja Za pravilno delovanje sigurnosnog ventila morate sami vršiti redovne kontrole te po potrebi odstraniti kamenac i proveriti da li je sigurnosni ventil možda blokiran Između rezervoara i sigurnosnog ventila ne smete ugraditi zatvarajući ventil jer bi time onemogućili funkcionisanje sigurnosnog ventila Elementi u elektronskoj kontrolnoj jedinici su pod...

Page 3: ...su preporučljive budući da se kod njih smanjuje efikasnost COP coefficient of performance odnosno stepen iskorišćenja i produžava se vreme zagrevanja odnosno povećava se broj radnih sati Budući da bojler s toplotnom pumpom u svom radu ujedno hladi prostor iskoristivost aparata je dvostruka grejanje vode hlađenje prostorija Delovanje bojlera za toplu vodu s toplotnom pumpom je potpuno automatsko Na...

Page 4: ...trošnja energije na izabranom profilu potrošnje A15 W10 55 3 kWh 3 01 3 03 4 74 4 77 Potrošnja energije na izabranom profilu potrošnje A20 W10 55 4 kWh 2 72 2 75 4 36 4 37 COPDHW A15 W10 55 3 3 9 3 9 4 0 4 0 COPDHW A20 W10 55 4 4 3 4 3 4 4 4 4 Snaga u stanju pripremljenosti 4 W 15 17 17 18 Rashladno sredstvo R134a R134a R134a R134a Količina rashladnog sredstva kg 0 950 0 950 1 100 1 100 Potencijal...

Page 5: ...e vode u rezervoaru biti manja ako senzor postavite na nižu poziciju period upućivanja protočne pumpe biće duži a razlika između temperature ogrevnog medija i postignute temperature vode u rezervoaru biće manja čime će i količina tople vode u rezervoaru zbog toga biti veća LEGENDA HV Dovod hladne vode modra rozeta IM Izlaz medija prenosnika toplote crna rozeta CV Cirkulacioni vod crna rozeta VM Ul...

Page 6: ...reba naročito voditi računa o tome da izabrana prostorija ne bude prašnjava budući da prašina štetno deluje na učinak toplotne pumpe Sl 2 Minimalni zahtevi za postavljanje aparata Sl 3 Odvod kondenzata Tokom rada toplotne pumpe u unutrašnjosti agregata stvara se kondenzat kog treba odvajati u izliv putem savitljive odvodne cevi Ø16mm za kondenzat na poleđini toplotne pumpe Količina kondenzata ovis...

Page 7: ...panja vode iz odvodnog otvora sigurnosnog ventila Kapajuću vodu možete da kanalizujete u odvod preko sabirnog nastavka kog ćete montirati ispod sigurnosnog ventila Odvodna cev nameštena pod ispust sigurnosnog ventila mora da bude postavljena u smeru pravo i nadole prema okolini u kojoj je temperatura takva da ne dolazi do zamrzavanja Ukoliko zbog neispravno izvedene instalacije nemate mogućnost da...

Page 8: ...larni kolektor U slučaju pada temperature dodatnog izvora grejanja i kod omogućenog cirkulisanja vode kroz prenosnik toplote može da se desi nekontrolisano oduzimanje toplote iz rezervoara vode Kod priključenja na druge izvore grejanja treba zato ispravno izvesti temperaturnu regulaciju dodatnog izvora U slučaju priključenja panela solarne energije kao spoljnog izvora toplote delovanje agregata mo...

Page 9: ...enosti toplotna pumpa održava temperaturu vode na 10 C Toplotna pumpa zagreva vodu na temperaturu u rasponu od 10 C do 65 C Od 65 C do 75 C vodu zagreva električni grejač Sl 7 Kontrolna tabla Uključenje isključenje toplotne pumpe Toplotnu pumpu uključite pritiskom na taster dugim najmanje 3 sekunde Ponovnim pritiskom na taster dugim najmanje 3 sekunde toplotna pumpa uvek prelazi u stanje pripremlj...

Page 10: ...Radu u režimu TURBO pokaže indikator koji svetli sve dok se voda u rezervoaru ne zagreje do izabrane temperature Nakon što je podešena temperatura postignuta funkcija se automatski isključi a indikator se ugasi Za konstantno uključenje TURBO režima rada pritisnite taster i držite ga pritisnutog izvesno vreme najmanje 3 sekunde Rad u konstantnom režimu TURBO rada stoji na indikatoru koji svetli Nak...

Page 11: ...najmanje 20 minuta minimalan period mirovanja kompresora Ukoliko u tom periodu dođe do zahteva za uključenje kompresora to neće biti izvršeno Na indikatoru slika 11 polagano pulsira signalna lampica LED4 interval 5 sekundi Nakon isteka vremena mirovanja kompresor i ventilator automatsko se ponovno pokreću u rad Na indikatoru stoji momentalan temperaturni nivo vode u rezervoaru U periodu mirovanja ...

Page 12: ... nataloži u unutrašnjosti rezervoara Nakon pregleda rezervoara tople vode a u ovisnosti o utvrđenom stanju Servisna služba preporučiće vam i datum naredne kontrole Usprkos brižljivoj proizvodnji i kontroli u radu bojlera za vodu s toplotnom pumpom može doći do određenih poteškoća i grešaka u radu koje u pravilu mora otkloniti ovlašćeni serviser Pre prijave eventualne greške svejedno proverite sled...

Page 13: ... facing downwards and in a non freezing area To ensure proper functioning of the safety valve the user should perform regular controls to remove limescale and make sure the safety valve is not blocked Do not install a shut off valve between the water tank and the safety valve as this would disable the operation of the safety valve Elements in the electronic control unit are energised even after yo...

Page 14: ...f heating or increase the number of operating hours Because the heat pump water heater cools its surroundings during operation the usefulness of the appliance is doubled heating water cooling air The operation of the heat pump water heater is fully automatic The appliance must be connected to water supply mains and to the power supply grid Leave enough room above the appliance for easier control a...

Page 15: ...9 07 14 06 57 Energy consumption with selected use profile A15 W10 55 3 kWh 3 01 3 03 4 74 4 77 Energy consumption with selected use profile A20 W10 55 4 kWh 2 72 2 75 4 36 4 37 COPDHW A15 W10 55 3 3 9 3 9 4 0 4 0 COPDHW A20 W10 55 4 4 3 4 3 4 4 4 4 Power in standby mode 4 W 15 17 17 18 Refrigerating agent R134a R134a R134a R134a Quantity of refrigerant kg 0 950 0 950 1 100 1 100 Global Warming Po...

Page 16: ...rage tank will be lower If you install the sensor in the bottom lower position the circulation pump operating intervals will be longer the difference between the temperature of the heating medium and the actual water temperature in the hot water storage tank will be lower and as a result the amount of hot water in the hot water storage tank will be greater LEGEND HV Cold water inlet H blue rosette...

Page 17: ... should also be taken in addition to the above instructions that there should not be a considerable amount of dust in the room as dust has a detrimental effect on the heat pump effect Fig 2 Minimum requirements for installation of the appliance Fig 3 Condensate discharge During operation of the heat pump condensate forms in the aggregate The condensate should be drained to the sewage system via a ...

Page 18: ...e dripping from the outlet opening on the safety valve The dripping water may be drained via trap into the drains the trap is mounted under the safety valve The outlet pipe which is mounted under the safety valve must be directed downwards in a place with a temperature above freezing If the installation does not allow draining of the water from the safety valve into the drains dripping can be avoi...

Page 19: ...ating Fig 5b Connection to a solar collector With a temperature decline of an additional heating source and with an enabled water circulation through the heat exchanger proper temperature control of the additional source must be ensured If the additional energy source is solar power the operation of the aggregate of the heat pump must be shut off The combination of two heating sources can lead to ...

Page 20: ...the heat pump switches to standby mode In the standby mode the heat pump maintains a water temperature of 10 C The heat pump heats the water in the range from 10 C to 65 C From 65 C to 75 C the water is heated by an electric heater Fig 7 Control panel Heat pump on off Switch on the heat pump by pressing the key and holding it for 3 seconds Press and hold for 3 s the key again to switch the heat pu...

Page 21: ...t temperature When the temperature is reached the function is switched off automatically and the indicator is turned off For constant activation press and hold 3 seconds the key Operation in the constant TURBO mode is indicated by the indicator that is lit When the temperature is reached the function is not switched off automatically To deactivate the function briefly press the key and the indicat...

Page 22: ...own off time If there is a request for compressor activation within this period of time the compressor is not switched on LED4 slowly flashes on the display unit Figure 11 5 second interval After the down off time the compressor and the fan are switched on automatically Current temperature level of the water in the tank is displayed on the display unit Temperature adjustment activation of the TURB...

Page 23: ...pending on the quality quantity and temperature of water The maintenance expert will recommend the date for the next inspection Despite careful production and control errors may occur during heat pump water heater operation which must be resolved by an authorised service technician Before calling your maintenance provider check the following Is everything OK with the power supply network Is the ai...

Page 24: ...03 2019 713822 ...