CONNECTION TO THE WATER SUPPLY

Before connecting the hot water tank, install the protective covering. Take off the top cover 

and insert the covering, make sure the slots on the covering match the connections on the 

hot water tank. Zip the zipper from top to bottom and tighten the tapes on the top edge of the 

covering. Replace the top cover. Insert the thermometer into the prefabricated sleeve on the 

front of the hot water tank; make sure to cut the opening for the sleeve into the covering. The 

connection to water supply network and fastening of the coloured rosettes shall be made 

according to the markings defined in previous Section.

For safety reasons the supply pipe must be fitted with a return safety valve that prevents the

pressure in the tank from exceeding nominal pressure by more than 0.1 MPa. The heating of 

water in the heater causes the pressure in the tank to increase to the level set by the safety 

valve. As the water cannot return to the water supply system, this can result in dripping from 

the outflow of the safety valve. The drip can be piped into the drain by installing a catching

unit just below the safety valve. The drainpipe fitted under the safety valve outflow must be

piped down in a straight vertical line and located in an environment free from the onset of 

freezing conditions.

In case the existing plumbing does not enable you to pipe the dripping water from the return 

safety valve into the drain, you can avoid the dripping by installing expansion tank on the 

inlet water pipe of the boiler. The volume of the expansion vessel shall be at least 3% of the 

volume of the hot water tank.

Key:

1. Return safety valve  

 

 

                

 

             

2. Test valve

3. Non-return valve  

 

 

 

 

4. Pressure-reducing valve     

 

 

5. Stop valve 

 

 

 

 

6. Test unit

7. Funnel outlet to the drain

8. Drain valve

H - Cold water

T - Hot water

The  water  heater  may  be  connected  to  the  household  water  supply  system  without  a 

pressure-reducing valve provided the supply mains pressure is less than 0.5 MPa. 

In  case  of  the  mains  pressure  exceeding  0.5  MPa,  a  pressure-reducing  valve  must  be 

installed to ensure that the pressure on the supply side of the heater does not rise above the 

nominal value.

GB

Summary of Contents for KGV 200-1

Page 1: ...KGV 200 300 ...

Page 2: ... following heating sources via heat exchanger central heating hot water system solar power heating pump Electric heater type R may be additionally installed on the flange 180mm or electric heater type SH to the connecting bushing G 6 4 INSTALLATION The heater should be installed in a dry room that is not subject to freezing conditions preferably in the vicinity of other sources of heating e g boil...

Page 3: ...ank height Insert the feeler into the channel and fix it with the enclosed rubber tap Recommended position h1 h2 of the feeler is marked on the drawing If the feeler is mounted higher than recommended the thermostat will react too fast the operating time of the circular pump will be shorter and the difference between the temperature in the hot water tank and heating media after the thermostat switc...

Page 4: ...tem this can result in dripping from the outflow of the safety valve The drip can be piped into the drain by installing a catching unit just below the safety valve The drainpipe fitted under the safety valve outflow must be piped down in a straight vertical line and located in an environment free from the onset of freezing conditions In case the existing plumbing does not enable you to pipe the dripp...

Page 5: ...various sources of heating are shown in the drawings below Connection to solar panels Connection to the central heating hot water system 1 Water heater 2 Central heating hot water system 3 Solar panel 4 Differential thermostat with sensors T1 T2 T3 T4 5 Bypass pump 6 Expansion tank 7 Non return valve 8 Safety valve 9 Air relief valve 10 Fill drain valve 11 Reduction valve 12 Drain valve 13 Stop va...

Page 6: ...ts of the water heater may be cleaned with a mild detergent solution Do not use solvents and abrasive cleaners Regular preventive maintenance inspections ensure faultless performance and long life of your heater The first of these inspections should be carried out by an authorised maintenance service provider about two years from the date of installation in order to inspect the wear of the corrosio...

Page 7: ...06 2008 766383 Gorenje Tiki d o o SI 1521 Ljubljana Magistrova 1 Slovenija Telefon 386 1 5005 600 Fax 386 1 5005 702 382 012 722 ...

Reviews: