29
Dear customer, thank you for purchasing our product.
PLEASE READ THE INSTRUCTIONS CAREFULLY PRIOR TO THE
INSTALLATION AND FIRST USE OF THE WATER HEATER.
The water heater has been manufactured in compliance with the relevant standards. Basic
technical characteristics of the product are listed on the label attached to the protective
cover.
The installation of the water heater must be carried out by qualified staff only. All repairs and
maintenance work in the interior of the water heater as well as limestone removal or testing/
replacement of the corrosion protection anode may only be carried out by an approved
maintenance service provider.
The hot water tank is designed in a manner which allows using the following heating sources,
via heat exchanger:
−
central heating hot-water system
−
solar power
−
heating pump.
Electric heater type R may be additionally installed on the flange
180mm, or electric heater type
SH to the connecting bushing G 6/4.
INSTALLATION
The heater should be installed in a dry room that is not subject to freezing conditions,
preferably in the vicinity of other sources of heating (e.g. boiler room).
TECHNICAL CHARACTERISTICS
KGV 200-1
KGV 300-1
KGV 300-2
A
1150
1550
1550
B
560
740
740
C
380
560
560
D
-
-
930
E
-
-
360
F
1010
1410
1410
HV
G 1
G 1
G 1
IM
G 1
G 1
G 1
CV
G 3/4
G 3/4
G 3/4
VM
G 1
G 1
G 1
TV
G 1
G 1
G 1
KGV 200-1 KGV 300-1 KGV 300-2
H1
300
480
480
H2
-
-
300
h1
100
155
155
h2
-
-
210
H1, H2 - Canal for palps
h1, h2 - Position of palps
HV - Cold water inflow (blue rosette)
IM - HE medium outlet (blue rosette)
CV - Circulation conduit (blue rosette)
VM - HE medium inflow (red rosette)
TV - Cold water outflow (red rosette)
GB
Summary of Contents for KGV 200-1
Page 1: ...KGV 200 300 ...