260938
• Connections may be carried out by a quali
fi
ed technician
only. The earthing protection must comply with the standing
regulations.
• Connection terminals are revealed when the connection box
cover is removed.
• Prior any attempted connection check that the voltage
indicated on the rating plate is in line with your home power
supply.
• The rating plate is located underneath the appliance.
• The appliance is manufactured for use with the power supply
voltage 230 V ~.
• The electric wiring should be equipped with a circuit breaker
able to isolate the appliance from the mains in all points,
with the distance between terminals of at least 3 mm in
open position. This may be done by means of fuses, safety
switches, etc.
• The connection should be selected in accordance with the
declared charge capacity of the mains and the fuse power.
• Such appliances are allowed to be mounted on one side next
to a high kitchen cabinet, the height of which may exceed that
of the appliance. On the opposite side however, only a kitchen
cabinet of equal height as the appliance is allowed.
• Upon the completion of installation, live wires and isolated
cables must be adequately protected against accidental
touching.
Upon each connection to the power supply the sensors of the
appliance are automatically adjusted to the environment to
ensure their proper function. All displays turn on and are fully
illuminated for a few seconds.
During the adjustment procedure the sensors must be free of any
objects, otherwise the adjustment procedure will be interrupted
until such objects are removed from the sensor surface. During
this period the regulation of the cooktop is impossible.
ATTENTION !
Before attempting any repairs on the appliance, disconnect
the power supply. In accordance with the mains voltage the
appliance should be connected in line with the attached diagram.
The earthing wire (PE) must be connected to the terminal
marked with the earthing symbol .
The connection cable must lead through the relief safety device,
protecting it from accidental pulling out. Upon the completion
of installation switch all the hotplates on for about 3 minutes to
check the proper functioning.
Basic adjustment of
sensors to the ambience
20
Connection to the power supplay