The appliance is designed for two-phase connection; it
can also be connected to a single phase.
• Two-phase connection
Install the jumper connectors on terminals/clips 4 and 5.
• Single-phase connection
Install the jumper connectors on terminals/clips 4 and 5,
and terminals/clips 1 and 2.
Note: Connection 3 is free.
The following may be used for connection:
• Rubber connection cables type H05 RR-F 4x1.5 with a
yellow-and-green protective conductor;
• PVC insulated connection cables type H05 VV-F 4x1.5
with yellow-and-green protective conductor, or other
equivalent or superior cables.