4
7
3238
The electronics in the appliance need cooling. The
appliance will automatically switch of if there is insui
cient air circulation. There are ventilation openings on
the underside of the appliance. It must be possible for
cool air to be drawn in through these openings. There are
outlet openings on the underside and at the front of the
appliance.
• An opening at least 140 mm high must be provided
on the back wall of the cabinet, along its entire width.
Furthermore, a minimum of 6 mm clearance must be
provided at the front side, along the entire width of the
cabinet.
• The hob is fi tted with a fan located in its lower part. In
case there is a drawer underneath the kitchen cabinet,
no small objects or paper must be kept there, as these
could be sucked in by the fan, causing damage to the
fan or the entire cooling system. Aluminum foil and infl
ammable substances or liquids (e.g. sprays) should also
not be stored in such drawers or placed near the hob.
Danger of explosion! There should be a clearance of
20 mm between the drawer contents and the fan entry
slots.
Lower kitchen cabinet
with a drawer
20
Ventilation
Summary of Contents for IC634CLB
Page 1: ...YOUR INDUCTION HOB MT INSTRUCTIONS FOR USE INSTALLATION AND CONNECTION IE GB...
Page 26: ...473238 26...
Page 27: ......