Type 

4108.2G31CB 

Model 

GC 341 UC 

Appliance dimensions (height/width/depth) mm 

46/300/510 

Mains voltage 

AC 230 V 

Operating voltage 

 

AC 230 V, 50 Hz 

 

A1 = small burner 

B = large burner 

Front 

1kW / A1 

Rear 

3kW / B 

Wok (kW) 

 

Cooking burners altogether (kW) 

 

4,0 

Cookeng burners altogether - liquid gas (g/h) 

290,8 

Gas type is indicated on the rating plate. 

G 20 

– 20mbar 

Gas connection (right) 

EN 10226  R1/2

 

 

Category 

    II2H3B/P 

Class 

* The built in height of the appliance is 64 mm 

MORA MORAVIA, s.r.o., Hlubočky – Mariánské Údolí, Česká republika                                     458293en 
 

WE RESERVE THE RIGHT TO ALTER THE 

SPECIFICATIONS  WITH  NO  INFLUENCE  ON  THE 

OPERATION OF THE APPLIANCE. 

 

Summary of Contents for GC341UC

Page 1: ...INSTRUCTIONS FOR USE MOUNTING AND CONNECTION Integrated gas hob EN...

Page 2: ......

Page 3: ...articular appliance may not have Check before the installation whether the local condition for the fuel distribution kind and pressure of gas are equal with setting up of the appliance This appliance...

Page 4: ...rds Nevertheless we strongly recommend that persons with impaired physical motoric or mental capacity or persons with inadequate experience or knowledge do not use the appliance unless attended by a q...

Page 5: ...r Wok 4 Front burner control button 5 Rear burner control button 6 Control button of the double burner 7 Cast iron cooking grating Control buttons Twin burner model Gas faucet closed High power Low po...

Page 6: ...es clean and free In certain models hob burners are thermally protected If the flame is accidentally extinguished spilled boiling draft of wind etc gas inlet is automatically shut and gas can not esca...

Page 7: ...he small flame symbol and back Operating positions are all positions between the two symbols Burners are ignited by means of ignition device fixed adjacent to each burner certain models only Models wi...

Page 8: ...t your cooking requirements Button positions between and are not recommended In these positions the flame is not stabilized and may be extinguished To shut the burner off turn the button to the right...

Page 9: ...small pots can be bought afterwards order number SAP 428741 Wok accessory for the double burner Wok Use the extension when preparing food in a Wok Place the extension over the burner grid support The...

Page 10: ...respective slots Oblique position of components may cause troubled ignition of burners Note Crown caps are coated with black enamel Discoloration of caps due to high temperatures is inevitable but it...

Page 11: ...tains are removed with special ceramic glass scraper Be careful however not to touch the hotplate surface with the scraper handle Fig 4 Handle the scraper with utmost care to avoid injuries Sugar and...

Page 12: ...Fault Cause Remedy Burner flame is not steady Wrong setting of gas Expert should set the gas escape properly Burner flame suddenly changes Incorrect assembly of burner components Assemble the burner...

Page 13: ...m width or more Suspended kitchen elements above the cooktop must be installed at such distance to provide enough room for comfortable working process The distance between the worktop and the hood mus...

Page 14: ...ing fan can be inserted below gas cooking hob Prior inserting the oven it is necessary to remove the rear kitchen element panel in the area of the oven opening Equally the front part of the element mu...

Page 15: ...ing regulations Connection terminals are revealed when the connection box cover is removed Prior any attempted connection check that the voltage indicated on the rating plate is in line with your home...

Page 16: ...es and isolated cables must be adequately protected against accidental touching ATTENTION Before attempting any repairs on the appliance disconnect the power supply In accordance with the mains voltag...

Page 17: ...ns check whether voltage indicated on the rating plate agrees with the installation in your home Authorized person must check the user connection voltage 230 V against N with the voltage meter Place t...

Page 18: ...ions of the local gas supplier Gas cooker is equipped with the EN 10226 R1 2 gas connection on the right side The appliance is delivered with hose adapter for bottled gas propane butane and with non m...

Page 19: ...conversion disconnect the appliance from the mains and shut the gas inlet off Replace the existing nozzles of declared nominal heat input with adequate nozzles for the new type of gas see table In cas...

Page 20: ...ally protected burners only only certain models 5 Ignition plug 6 Nozzle 7 Nozzle To provide access to the setting elements Remove the cooktop grid and burner crowns with caps Remove the control knobs...

Page 21: ...code 690780 690782 Setting screws are intended for liquid gas For natural municipal gas supply new setting of gas flow is required unscrew for not more than 1 5 turn from the end position Double burn...

Page 22: ...1 Rear 3kW B Wok kW Cooking burners altogether kW 4 0 Cookeng burners altogether liquid gas g h 290 8 Gas type is indicated on the rating plate G 20 20mbar Gas connection right EN 10226 R1 2 Category...

Page 23: ......

Page 24: ...4108 EN 2014 09 01 SAP 458293...

Reviews: