Caution!

 

 

Installation instructions

 

 

 

 

Dimensions of the built-

 

in hob opening

 

 

  To avoid any possible hazard, the appliance may be installed by qualified personnel only. 

  The veneer or the cover of furniture, respectively, in which the appliance is built in, has to 

be  prepared  from  materials  with  thermal  endurance  up  to  100°  C  as  minimum,  for 
preventing the changing of color and shape because of insufficient thermal endurance. 

  The cooking hob is intended for building into the worktop above the kitchen element 

of 600 mm width or more. 

  Suspended  kitchen  elements  above  the  cooktop  must  be  installed  at  such  distance  to 

provide enough room for comfortable working process. 

  The distance between the worktop and the hood must be at least  such as indicated 

in the  instructions for  installation  of  the  kitchen  hood,  but  in no case  it may  be  less 
than 650 mm. 

  Minimum distance between the appliance edge and adjacent high element is 150 mm. 

  The  use  of  hard  wood  decorative  borders  around  the  worktop  behind  the  appliance  is 

allowed, in case the minimum distance remains as indicated on the installation illustrations. 

   Minimum distance between the built-in cooktop and rear wall is indicated at the illustration 

for the installation of the built-in cooktop. 

 

150 

Summary of Contents for GC341UC

Page 1: ...INSTRUCTIONS FOR USE MOUNTING AND CONNECTION Integrated gas hob EN...

Page 2: ......

Page 3: ...articular appliance may not have Check before the installation whether the local condition for the fuel distribution kind and pressure of gas are equal with setting up of the appliance This appliance...

Page 4: ...rds Nevertheless we strongly recommend that persons with impaired physical motoric or mental capacity or persons with inadequate experience or knowledge do not use the appliance unless attended by a q...

Page 5: ...r Wok 4 Front burner control button 5 Rear burner control button 6 Control button of the double burner 7 Cast iron cooking grating Control buttons Twin burner model Gas faucet closed High power Low po...

Page 6: ...es clean and free In certain models hob burners are thermally protected If the flame is accidentally extinguished spilled boiling draft of wind etc gas inlet is automatically shut and gas can not esca...

Page 7: ...he small flame symbol and back Operating positions are all positions between the two symbols Burners are ignited by means of ignition device fixed adjacent to each burner certain models only Models wi...

Page 8: ...t your cooking requirements Button positions between and are not recommended In these positions the flame is not stabilized and may be extinguished To shut the burner off turn the button to the right...

Page 9: ...small pots can be bought afterwards order number SAP 428741 Wok accessory for the double burner Wok Use the extension when preparing food in a Wok Place the extension over the burner grid support The...

Page 10: ...respective slots Oblique position of components may cause troubled ignition of burners Note Crown caps are coated with black enamel Discoloration of caps due to high temperatures is inevitable but it...

Page 11: ...tains are removed with special ceramic glass scraper Be careful however not to touch the hotplate surface with the scraper handle Fig 4 Handle the scraper with utmost care to avoid injuries Sugar and...

Page 12: ...Fault Cause Remedy Burner flame is not steady Wrong setting of gas Expert should set the gas escape properly Burner flame suddenly changes Incorrect assembly of burner components Assemble the burner...

Page 13: ...m width or more Suspended kitchen elements above the cooktop must be installed at such distance to provide enough room for comfortable working process The distance between the worktop and the hood mus...

Page 14: ...ing fan can be inserted below gas cooking hob Prior inserting the oven it is necessary to remove the rear kitchen element panel in the area of the oven opening Equally the front part of the element mu...

Page 15: ...ing regulations Connection terminals are revealed when the connection box cover is removed Prior any attempted connection check that the voltage indicated on the rating plate is in line with your home...

Page 16: ...es and isolated cables must be adequately protected against accidental touching ATTENTION Before attempting any repairs on the appliance disconnect the power supply In accordance with the mains voltag...

Page 17: ...ns check whether voltage indicated on the rating plate agrees with the installation in your home Authorized person must check the user connection voltage 230 V against N with the voltage meter Place t...

Page 18: ...ions of the local gas supplier Gas cooker is equipped with the EN 10226 R1 2 gas connection on the right side The appliance is delivered with hose adapter for bottled gas propane butane and with non m...

Page 19: ...conversion disconnect the appliance from the mains and shut the gas inlet off Replace the existing nozzles of declared nominal heat input with adequate nozzles for the new type of gas see table In cas...

Page 20: ...ally protected burners only only certain models 5 Ignition plug 6 Nozzle 7 Nozzle To provide access to the setting elements Remove the cooktop grid and burner crowns with caps Remove the control knobs...

Page 21: ...code 690780 690782 Setting screws are intended for liquid gas For natural municipal gas supply new setting of gas flow is required unscrew for not more than 1 5 turn from the end position Double burn...

Page 22: ...1 Rear 3kW B Wok kW Cooking burners altogether kW 4 0 Cookeng burners altogether liquid gas g h 290 8 Gas type is indicated on the rating plate G 20 20mbar Gas connection right EN 10226 R1 2 Category...