20
Manual temperature setting:
- Use the
key and select the operating mode (yellow control lamp under is on).
- The display always shows the last setting of the water temperature; except on first turn on
of appliance when factory setting 35ºC is displayed.
- Use the
or
key to select new temperature. By pressing the key you increase/
decrease the temperature by 1ºC. Holding the key will speed up the process.
- After required temperature is set display flashes for 3 seconds and then shows the current
temperature again.
- In case of interruptions in power supply, the appliance resumes operating with the settings
adjusted before the interruption.
INDICATION:
• Control lamps:
-
Heating element operation
:
Green control lamp:
-
the heating element is on – the lamp is on
-
the heating element is off – the lamp is off
-
Mg anode
:
Red control lamp:
-
the lamp is off
– anode is active
-
the lamp is on – anode may be worn out
Warning!
When the water heater is out of use for longer
period of time, the signal lamp may indicate that the
Mg anode is worn out in spite of the fact that the Mg
anode is still active. In this case open the hot water tap
(fresh water flow into water heater). If the signal lamp
switches off, the water heater operation is not impaired.
If not, call the nearest authorized service provider
-
Water heater operation
:
Yellow control lamps:
-
protection against freezing – the lamp is on or
-
cost saving temperature setting – the lamp is on or
-
manual setting– the lamp is on
• LED display:
-
Water temperature of in the heater
:
from 0ºC to 85ºC
-
When set, display of the adjusted temperature
:
(flashing from 0ºC to
85ºC)
-
Error indication
:
-
display
E1
–
failure of the electronic regulator sensor (the
heating element doesn’t operate)
-
display
E2
-
failure of the thermometer sensor (water heater
operates)
-
display
E3
-
failure of both sensors (water heater doesn’t
operate)
GB
Summary of Contents for GBFU 50-150EDD/V9
Page 1: ...GBFU 50 150EDD V9...