![Gorenje G340UX Instruction Manual Download Page 7](http://html1.mh-extra.com/html/gorenje/g340ux/g340ux_instruction-manual_2245128007.webp)
8
Warning: these tasks may only be carried out by a qualified technician, authorized by the
gas distributing company or authorized service center!
TECHNICAL INFORMATION (TABLE 1)
GTW751UB
GT641UB
GT641UW
GW761UX
Appliance dimension (mm)
750
580
750
Operating voltage
220-240 V~, 50/60 Hz
Burner
A: Auxiliary burner (1,0kW)
SR: Semirapid burner (1,75kW)
R: Rapid burner (3,0kW)
MW: Bruciatore Mini-Wok = 3,3kW
TC: Bruciatore Tripla corona = 3,8kW
Front left
A
R
TC
Rear left
SR
SR
-
Front central
TC
-
A
Rear central
-
-
SR
Front right
SR
A
SR
Rear right
R
SR
R
Category Gas usage
G20 = 20mbar , G30 = 30mbar , G20 = 13mbar
Total Power (W)
11300
7500
11300
GTW641UB
G640UX
GW951UX
GTW951UB
GW961UX-SA
Appliance dimension (mm)
580
600
880
880
Operating voltage
220-240 V~, 50/60 Hz
Front left
MW
R
A
TC
Rear left
SR
SR
SR
-
Front central
-
-
TC
A
Rear central
-
-
-
SR
Front right
A
A
SR
SR
Rear right
SR
SR
R
R
Category Gas usage
G20 = 20mbar , G30 = 30mbar
Total Power (W)
7800
7500
11300
11300
NOZZLE TABLE
Burner
A
SR
R
MW
TC
Rated heat output (kW)
1.00
1.75
3.00
3.30
3.80
Ø INJECTOR (mm)
G30/G31
28..30/30-37mbar
0.50
0.65
0.85
0.85
0.98
G20
20mbar
0.72 - X
0.97 - Z
1.28 - H3
1.28 - T
1.35 - K
G20
13mbar
0.84
1.03
1.45
1.48
1.65
Ø BY-PASS (mm)
G30/G31
28..30/30-37mbar
0.27
0.34
0.42
0.55
0.62
G20
20mbar
REG.
REG.
REG.
REG.
REG.
G20
13mbar
REG.
REG.
REG.
REG.
REG.