WARNING!
• Before any intervention, disconnect the appliance from the power mains. Connect
the appliance in compliance with the electric connections diagram supplied; make
sure the relevant network voltage is observed! The ground wire (PE) should be
connected to the clip indicated by the earthing symbol.
• The mains cable should be fed through the fastening clip which protects it from
being accidentally pulled out.
• After connecting the appliance, turn on all cooking zones / heaters for
approximately three minutes to make sure they are operating correctly.
Connecting:
• Incorrect connection may destroy parts of the appliance, making the warranty void.
• Before connecting the appliance, make sure the voltage indicated on the rating
plate is consistent with the voltage in your home network. Connection voltage should
be checked by a qualified technician using a corresponding measuring device!
• Connection cable on the back of the appliance should be led in such way that it
does not touch the appliance back wall, as this part will get very hot during
operation.
The following can be used for connection:
• Type H05RR-F rubber connection cables with a greenyellow protective wire,
• Type H07RN-F rubber connection cables with a greenyellow protective wire.
CONNECTING THE COOKING HOB TO THE GAS SUPPLY
• The appliance must be connected in compliance with all relevant regulations, and it may only be used in well ventilated
/ aerated rooms. Before connecting or using the appliance, please read the instruction manual.
• Before installing and connecting, make sure the local natural gas supply network and connection (type of gas and
pressure), are compatible with your appliance version.
The category with the related types of gas can be used are included in Table 1
• The version of this appliance is indicated on the rating plate.
• This appliance is not suitable for connection to a burning fumes exhaust system (i.e. a chimney).
The appliance must be installed and connected in compliance with the relevant effective installation regulations. Special
care must be taken to ensure adequate ventilation / aeration.
Connection
• When connecting the appliance to the gas supply, follow the regulations of the local
gas distributor.
• On the lower side, the cooking hob is fitted with a gas connection plug with a ISO7-
1 R1/2 thread.
• Also supplied with the appliance is an adapter for liquid gas, a taper male, and a
non-metal gasket.