CONNECTING THE WATER HEATER
TO THE POWER SUPPLY NETWORK
Before connecting to the power supply network, install a power
supply cord in the water heater, with a min. diameter of 1.5 mm
2
(H05VV-F 3G 1.5 mm
2
). To do this, the protective plate must be
removed from the water heater.
In the electrical installation, please install a disconnect switch to
separate all poles from the power supply network in accordance
with the national regulations.
LEGEND
1
Connection terminal
2a
Thermal cut-out
2
Thermal cut-out
3
Electronic regulator
4a
Electric heating element
(1000 W or 1600 W)
4b
Electric heating element
(1000 W)
5
Temperature sensor
6
Temperature sensor
L
Live conductor
N
Neutral conductor
Earthing conductor
CAUTION: Before any intervention into the interior of the water heater,
disconnect it from the power supply network! This intervention may only
be performed by a trained professional!
Fig. 5:
Removing the protective cover
Fig. 6:
Electric installation
1
N
230 V~
H2
H1
K1
1
2
3
K2
T1
T3
T2
T4
1
2
3
L
N
L
5
6
3
2a
4b
4a
2b
489390
16
EN
Summary of Contents for FTG 30-100 E5
Page 1: ...FTG 30 100 E5 www gorenje com BRUGSANVISNING INSTRUCTIONS FOR USE DA EN...
Page 22: ...489390 22...
Page 23: ...489390 23...