Instructions for Use
9
Troubleshooting
Problem:
Cause or remedy
After connecting to the power
mains, the appliance does not
operate:
• Make sure the wall outlet is powered and that the appliance is
plugged in.
Cooling system has been working • Too high environment temperature.
continuously for a long period of
• Door is open too often or it is left open too long.
time:
• Door is not closed appropriately (there may be dirt between the
door and the refrigerator, the door may be tilted, the seal
should be checked, etc.).
• Too much fresh food was inserted.
• Insufficient compressor and condenser cooling. Check the air
circulation behind the appliance and clean the condenser.
Ice accumulation in the freezer
interior is a result of:
• Poor door sealing. If the seal is dirty or damaged, clean or
replace it.
• Door is opened too often or left open too long.
• Placing warm food into the freezer.
Signal light
D
is flashing:
• Frequent opening of the door, door open too long.
• Door not closed properly (particle between door gasket,
sagged door, damaged gasket, etc...).
• Excessively long power failure.
• Excessive quantity of fresh food inserted at once.
Door won’t open easily:
• If you wish to open freezer door immediately or shortly after
closing it, you may feel rather strong resistance. When the
freezer door is opened, some cool air escapes from the freezer
compartment and it is replaced by warm air from the
environment. When this air is cooled, a sub-pressure builds up,
causing resistance to door opening. After a few minutes, the
condition is normalized and the door can be easily opened
again.
Occurrence of murmur after
closing the door:
• After closing the door, some murmur can occur. This
phenomenon is normal and is due to pressure equalisation.
If none of the above reasons seems to match your problem, please contact the nearest service center and
state the type, model and serial number as indicated on the label with basic information attached in the
appliance interior
.
Noise
Cooling in refrigerating-freezing appliances is
enabled by the cooling system with a compressor
which produces noise. How noisy the appliance is
depends on where it is placed, how it is used and
how old the appliance is.
•
During the operation
of the compressor the
noise of liquid is heard and when the
compressor is not operating, the refrigerant flow
is heard. This is a normal condition and it has no
influence whatsoever on the lifetime of the
appliance.
•
After starting the appliance,
the operation of
the compressor and the refrigerant flow may be
louder, which does not mean that something is
wrong with the appliance and it has no influence
on the lifetime of the appliance. Gradually the
noise is reduced.
WE RESERVE THE RIGHT TO ALTER THE SPECIFICATIONS THAT DO NOT AFFECT
THE OPERATION OF THE APPLIANCE.