10
5.
Install the wall hanger [E] at the appropriate level.
6. Install the telescopic column of the masking cover.
a)
Trace a vertical line on the wall to indicate the center of the cooker plate,
b)
Hold a hood hanger profile [D] to the wall (Fig. 3), set it symmetrically in relation to the central line,
with the distance between the holes in the profile and the cooker plate amounting to min. 960 mm,
level the profile preliminarily, indicate the spacing of mounting holes on the wall,
c)
Drill the holes as indicated on the wall, using drills of diameter corresponding to the attached
expansion plugs, drive the plugs in and then screw the hanger profile to the wall
a)
Hang the hood body on the installed hanger [D], level it with adjusting screws [J] and then tighten the
screw [I] preventing the hood from sliding off the hanger,
b)
If required, install the appropriate conduit for discharge of air to a ventilation duct,
c)
Attach the telescoping column of the masking cover [A and B] on the mounted hood (Fig. 1)
d)
Extend the top masking cover [N] (Fig. 4) to the required height, indicate its max. reach on the center
line, remove the cover,
e)
Hold the hanger of the top masking cover [E] at the center line, at a distance of 65 mm from the
indicated point of max. reach (Fig. 4), indicate the mounting holes on the wall and install the hanger as
described under d). Install the air guide [F] if required (Fig. 4), using the same mounting screws,
f)
Install the masking cover column again and, using apprpriate screws, fix it to the bottom masking cover
and the top hanger profile,
g)
Connect the hood to the power supply network.
After connecting the device to the power supply network (in accordance with the requirements defined
above) it is necessary to check the lighting of the hood and whether its motor works correctly.
The wall socket shall be accessible for disconnecting the plug after the hood is installed.
In the extractor mode air is discharged to the outside by a special conduit. In that setting any carbon filters
shall be removed.
The hood can be connected to the opening discharging air to the outside by means of a rigid or
flexible conduit of 150 mm diameter, and appropriate clamps for conduits which should be purchased in a
shop selling installation materials.
A qualified installer should be commissioned to make the connection
In this option filtered air returns to the room through cut outs on both sides of the top funnel. In this setting it
is necessary to install the carbon filter; installation of the air exhaust guide is recommended.
1. Installation of the wall hanger
2.
Installation of the hood
3. Connecting to the power network and operation check
4. Setting the operation mode of the kitchen extractor hood
4.1 Setting the air extractor mode of operation of the hood
4.2 Setting the odour absorber mode of operation of the hood
4.3 Fan speeds
Summary of Contents for DVG 8340 E
Page 1: ...Kitchen extractor hood Kaminhaube Typ DVG 8340 E BEDIENUNGSANLEITUNG INSTRUCTIONS FOR USE ...
Page 13: ...13 ...
Page 14: ...14 Notes ...
Page 15: ...15 Notes ...
Page 16: ...16 ...