![Gorenje Tiki GBK 100 LN/RN Instructions For Use Manual Download Page 15](http://html1.mh-extra.com/html/gorenje-tiki/gbk-100-ln-rn/gbk-100-ln-rn_instructions-for-use-manual_2246310015.webp)
15
Dear customer, we thank you for purchasing our product.
PLEASE READ THE INSTRUCTIONS THOROUGHLY PRIOR TO THE INSTALLATION AND
FIRST OPERATION OF THE WATER HEATER.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH
REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE
AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION
CONCERNING USE OF THE APPLIANCE BY PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE
APPLIANCE.
This water heater has been manufactured in compliance with the relevant standards and tested by the relevant
authorities as indicated by the Safety Certificate and the Electromagnetic Compatibility Certificate. Its basic technical
properties are stated upon the nameplate, glued between the connection pipes. The water heater may be connected
to water and electric power supply only by a qualified specialist. The reach in its inside due to the repair or removal of
limestone and checking and replacement of anti-corrosion protection anode may be performed only by an authorised
service workshop.
INSTALLATION
The water heater shall be built as close as possible to the outlets.It has to be fitted to the wall using appropriate rag bolts
with minimum diameter of 8 mm. In case the wall in question cannot support the weight three times that of the water
heater filled with water, the relevant section of the wall where the heater is to be installed, must be suitably reinforced.
GBK water heater must be mounted to the wall in the upright position. Only GBL 50 and GRL 80 models may be mounted
horizontally to the ceiling. These water heaters may not be wall- or floor-mounted as this could damage the heaters.
TECHNICAL CHARACTERISTICS OF WATER HEATER
Type
GBL 50
GBL 80
GBK 80 L/D
GBK 100 L/D
GBK 120 L/D
GBK 150 L/D
GBK 200 L/D
Model
GBL 50 N
GBL 80 N
GBK 80 LN/RN GBK 100 LN/RN GBK 120 LN/RN GBK 150 LN/RN GBK 200 LN/RN
Volume [l]
50
80
80
100
120
150
200
Rated pressure [MPa]
0,6
Weight / Filled with water [kg]
27/77
33/113
51/131
56/156
62/182
72/222
90/290
Anti-corrosion protection of tank
Emailed & Mg Anode
Power of electrical heater [W]
2000
Connection voltage [V
~
]
230
Protection class
I
Degree of protection
IP 25
Heating time to 75°C
1)
[h]
1
55
3
05
3
05
3
55
4
35
5
45
7
40
Quantity of mixed water at 40° [l]
80
117
151
189
226
276
360
Energy consumption
2)
[kWh/24h]
1,20
1,46
1,39
1,58
1,77
2,05
2,50
1) Time required for the electric heating element to heat the entire tank volume, at the water supply temperature of 15°C.
2) Power consumption required for the temperature of water in the water heater to be maintained at 65°C, at the room temperature
of 20°C, measured in accordance with the DIN 44532 standard.
TECHNISCHE EIGENSCHAFTEN DES WARMWASSERBEREICHERS
GBK 80 L/D
GBK100 L/D
GBK 120 L/D
GBK 150 L/D
GBK 200 L/D
Nominal pressure [MPa]
0,6
Max. inlet temperature of heating medium [°C]
85
Surface of transmitter [m
2
]
0,72
0,88
Heat flow of heat transmitter
3)
[W]
14400
17600
3) Heating medium: inlet temperature 70°C, flow 3000 l/h.
Sanitary water: inlet temperature 10°C, outlet temperature 45°C, flow 437 l/h.
GB
Summary of Contents for GBK 100 LN/RN
Page 1: ...GBK GBL...
Page 13: ...13 GBK GB c GB GBK y K K a c y 1 2 3 4 5 6 7 c H T RUS...
Page 14: ...14 1 2 3 2 x 1000 4 5 L N Ha c 25 75 E 55 B f B 10 B He B c o a RUS...
Page 29: ...29 1 2 3 e 4 5 6 7 H T GBK GB GB GBK Zp tn veden Energetick zdroje BG...
Page 30: ...30 BG 1 2 3 2 x 1000 W 4 5 L N e e 25 C 75 C e E e e 55 C f 10 C T e c He 2 a...
Page 37: ...37 MK 1 2 3 4 5 6 7 H a T GBK GB GB GBK 3...
Page 38: ...38 MK 1 2 3 2 1000 W 4 5 L N 25 75 55 10 36...
Page 41: ...41 1 2 3 4 5 6 7 H T GBK GB GB GBK 3 mm SRB...
Page 42: ...42 25 75 55 10 36 1 2 3 2 x 1000 W 4 5 L N SRB...
Page 67: ...67...
Page 68: ...766367 03 2010...