3
Termination Instructions —
TE Connectivity
®
CeeLok FAS-T
®
Connector System
GORE
®
Aerospace
Ethernet Cables
Figure 18: Marking each primary
Figure 22: Stripping and crimping primaries
Figure 19: Stripping a primary
Figure 20: Primaries that have been
stripped
Figure 17: Removing the foil edge
Figure 21: Marking a primary
9. With cutters, cut the foil edge where it meets the tape, and
tear the foil along the tape edge (Figure 17).
10. Mark each primary 0.8 inch from the end of the cable (Figure 18).
11. Use 22-gauge hand strippers to strip the outer layer of
dielectric off from the edge to the mark on each primary.
If the strippers do not give a clean cut, use your fingers or
tweezers to remove slug (Figures 19–20).
12. Mark each primary at 0.125 inch from the end (Figure 21).
13. Install the K1850 positioner for the pin contacts into the
M22520/2-01, and select setting 3. To prevent stray wire
strands during crimping, strip and crimp one primary at a time
(Figure 22).