GORE TE Connectivity CeeLok FAS-T Termination Instructions Download Page 2

2

Termination Instructions —  

TE Connectivity

®

 CeeLok FAS-T

®

Connector System

GORE

®

 Aerospace

Ethernet Cables

Terminating the Plug Connector (Termination A)

1. Slide one piece of the TAT onto the cable. 
2. Measure and mark the cable 1.0 inch from the plug end of  

the cable (Figure 11).

Figure 11: Marking the cable 

Figure 12: Slitting the cable jacket 

Figure 15: Marking each pair

Figure 13: Exposing the braid 

Figure 16: Wrapping the pair

Figure 14: Exposing the foil

3. Using a scalpel or scissors, slit the cable’s jacket from its edge 

to the mark (Figure 12).

4. Using needle-nose pliers, gently pull the outer jacket down  

the cable until you have exposed approximately 2 inches of 
braid (Figure 13).

5. With your fingers, push the braid back over the cable to expose 

approximately 2 inches of the foil (Figure 14).

6. Remove the white filler as far down as possible.
7. Mark each pair 0.9 inch from the end of the cable (Figure 15).

8. Cut a 0.5-inch piece of copper or polyimide tape for each 

pair of the cable. Wrap a piece around each pair at the mark 
made in Step 7, making sure that the foil shield is as tight as 
possible (Figure 16).

Summary of Contents for TE Connectivity CeeLok FAS-T

Page 1: ...ined tubing TAT 4 Cut the cable to the desired assembly length minus 1 9 centimeters cm to allow for length of the connectors i e 1 3 cm for the plug connector and 0 6 cm for the receptacle connector...

Page 2: ...3 Using a scalpel or scissors slit the cable s jacket from its edge to the mark Figure 12 4 Using needle nose pliers gently pull the outer jacket down the cable until you have exposed approximately 2...

Page 3: ...tear the foil along the tape edge Figure 17 10 Mark each primary 0 8 inch from the end of the cable Figure 18 11 Use 22 gauge hand strippers to strip the outer layer of dielectric off from the edge t...

Page 4: ...re 25 Brushing the braid Figure 27 Marking the cable Figure 28 Slitting the cable jacket Figure 26 Returning the outer jacket 16 With your fingers or needle nose pliers push the outer jacket as close...

Page 5: ...sible 7 Markeach pair 0 9 inch from the end of the cable Figure 31 8 Cut a 0 5 inch piece of copper or polyimide tape for each pair of the cable Wrap a piece around each pair at the mark made in Step...

Page 6: ...acts into the M22520 2 01 and select setting 3 To prevent stray wire strands during crimping strip and crimp one primary at a time Figure 38 14 Using an insertion tool insert each primary into the con...

Page 7: ...e 45 Trimming excess braid on plug Figure 47 Taping the plug Figure 44 Attaching Band It to receptacle Figure 50 Shrinking tubing on receptacle Figure 46 Trimming excess braid on receptacle Figure 48...

Page 8: ...V15 GORE Aerospace Ethernet Cables TE Connectivity and CeeLok FAS X are trademarks of the TE Connectivity LTD family of companies BAND IT Tie Dex and Tie Dex II are registered trademarks of BAND IT ID...