Reinstall the front panel and the cover.
Connect the control box to the socket on the burner with the signal cable. The
socket is positioned above the mains inlet on the burner (No. 1, fig. 2.2) and at
the left of the bottom of the control box (fig. 2.1). Fasten the stop screws in both
ends of the cable. Do not disconnect or connect the cable when the burner is
mains supplied 230 V.
1. Signal cable connection
15-poles D-sub with straight coupling.
2. Mains supply (230V) with fuse (S).
(L) phase, (PE) earth and (N) zero.
3. Feed screw mains socket (230 V)
The burner is as standard delivered with 3 m signal cable. Consult the authorized
PellX dealer if you need a longer cable. There is a maximum limit allowed for
the length of the cable.
Connection in the signal cable:
1-2:
Circuit board feed 12 Vac
3-4: Flame
sensor
5:
Control signal for ash screw
6:
Control signal for ignition element
7:
Control signal for combustion fan
8:
Control signal for feed screw
14-15:
3.3 Vdc from circuit board
L
PE
N
2
3
1
S
Fig. 2.2 Socket on the burner.