Goodwe SDT SERIES User Manual Download Page 2

02

02
02
03
05

3 Installation

3.1 Mounting instruction
3.2 Inverter Overview and Package
3.3 Inverter Installation
3.4 Electrical Connection

 

11

11
12
16
16
16

4 System Operation

4.1 Indicator Lights
4.2 User Interface and Use of the Display
4.3 Error message
4.4 Wi-Fi Reset & Wi-Fi Reload
4.5 Special Adjustable Setpoints

 

17

5 Troubleshooting

18

6 Technical Parameters

20

7 Certificates

20

8 Maintenance

01

2 Safety measures

01

1 Symbols

Summary of Contents for SDT SERIES

Page 1: ...46788 sales goodwe com service in goodwe com GoodWe Italy Via Cesare Braico 61 72100 Brindisi Italy T 39 338 879 38 81 39 831 162 35 52 valter pische goodwe com sales operazioni topsenergy com goodwe...

Page 2: ...Electrical Connection 11 11 12 16 16 16 4 System Operation 4 1 Indicator Lights 4 2 User Interface and Use of the Display 4 3 Error message 4 4 Wi Fi Reset Wi Fi Reload 4 5 Special Adjustable Setpoin...

Page 3: ...ed When exposed to sunlight the PV array will generate dangerous high DC voltage Please operate according to our instructions or it will result in danger to life PV modules should have an IEC61730 cla...

Page 4: ...on bolts in the accessories bag 3 Hold the inverter by the side groove as Figure 3 3 2 2 4 Install the inverter on the wall mounted bracket Please refer to Figure 3 3 2 3 For dissipation of heat and c...

Page 5: ...ue line conductor shall be black or brown preferred protective earth bonding line shall be yellow green Fix moment 0 6N m the connector of AC cable to the corresponding terminals 3 4 2 AC circuit brea...

Page 6: ...t buckle can not crimping the wire Negative connector Positive connector DEVALAN SERIES MC4 SERIES AMPHENOL SERIES QC4 10 SERIES There are four types of DC connectors DEVALAN SUNCLIX MC4 AMPHENDL H4 a...

Page 7: ...ator LED on the front cover will light up For none wi inverter the buzzer in inverter will keep ringing 1 minute and ring again after half an hour unless the fault is resolved This function is only av...

Page 8: ...e switching fault occurrence or key operation In all levels of menu if no action is taken for 20 seconds the backlight of the LCD display will be switched o and the display will automatically revert t...

Page 9: ...t of LCD will power o and screen return to the rst level menu If you change the Language the LCD screen will show Setting after 10 seconds then show 14 13 50Hz GridDefault Lock No Error UtilityLoss 19...

Page 10: ...ed to enter a password before setting up power limit The default password is 1111 only for Australian security regulations Set OK or Set Fail Set time From the rst level Set language menu short press...

Page 11: ...n 3 If the problem still exists please call the local service o ce 1 Disconnect DC switch take o the AC connector and then measure the voltage between line and neutral in connector Check if it conform...

Page 12: ...r rstly and then disconnect DC breaker Wait 5 minutes until the residual voltage has been drained 1 Please make sure the voltage of PV string will not exceed the Max DC voltage 20 19 GW12KT DT 18000 1...

Reviews: