09 Parameters
User Manual V1.0-2022-10-15
24
Technical Data
LX C 101-10
LX C120-10
Usable Energy (kWh)* 1
101.38
119.81
Battery Module
LX C9.2-10: 38.4V 9.21kWh
Number of Modules
11
13
Cell Type
LFP (LiFePO4)
Cell Configuration
132S2P
156S2P
Nominal Voltage (V)
422.4
499.2
Operating Voltage Range (V)
369.6~468.6
436.8~553.8
Nominal Dis-/Charge Current (A)
*2
100
Nominal Power (kW)
*2
42.24
49.92
Short-Circuit Current
4.0kA [email protected]
4.1kA [email protected]
Operating Temperature (℃)
Charge: 0 ~ +45 / Discharge: -20 ~ +50
Relative Humidity(%)
0~95%
Max. Operating Altitude (m)
2000
Communication
CAN+RS485
Weight (Kg)
1120
1280
Dimensions (W×H×D) (mm)
1155×1650×730
Ingress Protection Rating
IP21
Storage Temperature (℃)
0~+35 (﹤ One Year); -20~0 or +35~+45 (﹤ Three
Months)
Mounting Method
Grounded
Round-trip Efficiency
*1
96.0%
Cycle Life
*3
4000
Standard
and
Certification
Safety
IEC62619, IEC62040, IEC63056
EMC
IEC/EN61000-6-1/2/3/4
Transportation
UN38.3
*1: Test conditions, 100% DOD, 0.2C charge & discharge at +25±2 °C for battery system at
beginning life. System Usable Energy may vary with different Inverter.
*2: Nominal Charge/Discharge and power derating will occur related to Temperature and SOC.
*3: Based on 2.5~3.65V voltage rang @25±2℃ of Cell under 0.5C/0.5C test condition and
100%DOD 80% EOL.
09 Parameters