background image

 

 

17

  

 

cable waterproof ring RS485 cover

crystal head

screw cap

insulator

Figure 4.4-2

PIN

1
2

3
4
5
6
7
8

RESERVED

RX_RS485B

RX_RS485A
TX_RS485B
TX_RS485A

Function

Color

orange/white

orange

green/white

blue

blue/white

green

brown/white

brown

RS485 waterproof assembly

RESERVED

RESERVED
RESERVED

 

4.5 WiFi Communication Connection 

Install the antenna to inverter. Refer to Figure 4.5-1. 

Figure 4.5-1

 

4.6 USB Communication Connection

 

The USB communication is used for firmware update only

 

Please follow below Figure 4.6-1 to implement USB connection:  

Summary of Contents for ES Series

Page 1: ...ES Series User Manual HYBRID PV INVERTER 350 00035 T0 ...

Page 2: ...6 3 3 Selecting The Mounting Location 6 3 4 Mounting 8 4 Electrical Connection 9 4 1 AC Output Connection 9 4 2 PV Connection 11 4 3 Battery Connection 13 4 4 RS485 Communication Connection 15 4 5 WiFi Communication Connection 17 4 6 USB Communication Connection 17 5 LED Lights Illustration 18 6 Error Messages 18 7 Specifications 19 8 Certificates 21 ...

Page 3: ... the battery capacity is insufficient to meet own consumption requirements load get electricity from the public grid GoodWe ES series inverter is design for both indoor and outdoor use Figure 1 1 Basic hybrid PV system overview 2 Important Safety Warning Before using the inverter please read all instructions and cautionary markings on the unit and this manual Store the manual where it can be acces...

Page 4: ...s of the product he package produc tipped over or slun than 6 identical p y the package pr e humidity and mus voltage exists in th nce at least 5 m in the inverter to fu ance and connection c shock or damage erve a warning in electric shock sed as household w must always be trans at the arrows alway can be recycled ct should be handle g packages may be s roduct must be st be stored under c he inve...

Page 5: ...ed to prevent such damage to the inverter otherwise the inverter may be damaged and the warranty annulled z Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter otherwise the inverter may be damaged and the warranty annulled z PV modules should have an IEC61730 classA rating If the maximum AC mains operating voltage is higher than the PV ...

Page 6: ...unted bracket x1 inverter x1 or or antenna x1 expansion bolt x6 electrician z Machine shipping to Australia shall comply with Australia National Wiring Rules 3 Installation 3 1 Packing List Before installation please inspect the unit Be sure that nothing inside the package is damaged You should have received the following items inside of package ...

Page 7: ...ts 2 PV input ports 3 DC switch optional 4 Wireless port 5 USB port 6 RS485 ports 7 AC output ports 3 3 Selecting The Mounting Location Mounting location should be selected based on the following aspects z The installation method and mounting location must be suitable for the inverter s weight and dimensions z Mount on a solid surface z Select a well ventilated place sheltered from direct sun radi...

Page 8: ...d NOT be installed near inflammable and explosive items Any strong electro magnetic equipment should be kept away from installation site z Product label and warning symbol shall be clear to read after installation z Please avoiding direct sunlight rain exposure snow lay up when installing direct sunlight rain exposure snow lay up Figure 3 3 2 no direct sunlight norain exposure no snow lay up z In ...

Page 9: ... in diameter and 80 mm deep Refer to Figure 3 4 1 2 Fix the wall mounting bracket on the wall with six expansion bolts in accessory bag 3 Carry the inverter by holding the handles Refer to Figure 3 4 2 4 Place the inverter on the wall mounted bracket Refer to Figure 3 4 3 Figure 3 4 4 5 Fix the inverter with the lock plate in accessory bag Refer to Figure 3 4 5 6 Use flat head screw in accessory b...

Page 10: ...ure 3 4 4 a b detail a detail b Figure 3 4 5 Figure 3 4 6 flat head screw paklock 4 Electrical Connection 4 1 AC Output Connection Before connecting to Grid and Load please install a separate AC breaker 250VAC 30A between inverter and Grid This will ensure the inverter can be ...

Page 11: ... It should meet GoodWe product Spec 2 Measure the impedance between neutral cable and earth cable make sure it is not excess than 10 ohm 3 Disconnect AC breaker between inverter and Grid 4 Disconnect screw cap from insulator 5 Disconnect waterproof ring from insulator 6 Put the cable through the components in this order screw cap waterproof ring insulator AC cover and AC terminal Refer to Figure 4...

Page 12: ... 1 4 Figure 4 1 5 cable core section after crimp Figure 4 1 6 Figure 4 1 7 L line N neutral PE earth back up terminal grid terminal pan head screw 4 2 PV Connection z Before connecting the PV panels ensure the plug connectors have the correct polarity Incorrect polarity could permanently damage the inverter ...

Page 13: ...design based on the minimum value that the design of the PV functional grounding in the inverter was based on The minimum value of the total resistance 19 33kΩ that the system must meet There is a risk of shock hazard if the total minimum resistance requirement is not met There are two types of PV plugs sunclix series and MC4 series Refer to Figure 4 2 1 Figure 4 2 1 sunclix series MC4 series The ...

Page 14: ...n that electric arc occurs when connecting battery to the inverter without use a DC breaker z It s very important for system safety and efficient operation to use appropriate cable for battery connection To reduce risk of injury please use the proper recommended cable size Refer to Figure 4 3 1 Description Size A External diameter of the wire 10mm 12mm B Sectional area of conducting materials 20mm...

Page 15: ...ion 1 Check the nominal voltage of batteries The nominal input voltage should meet GoodWe product Spec 2 Disconnect DC breaker between inverter and battery 3 Disconnect screw cap from insulator 4 Disconnect waterproof ring from insulator 5 Put the cable through the components in this order screw cap waterproof ring insulator battery cover and battery terminal Refer to Figure 4 3 2 6 Compress the t...

Page 16: ...ble core section after crimp red cable black cable positive terminal negative terminal Figure 4 3 6 Figure 4 3 7 hexagon head screw pan head screw 4 4 RS485 Communication Connection An RS485 interface is used for Li ion and EzMeter communication The cable length should not exceed 800m The connection method of RS485 refer to Figure 4 4 1 ...

Page 17: ...nnect waterproof ring from insulator 4 Put the cable through the components in this order screw cap waterproof ring insulator RS485 cover Refer to Figure 4 4 2 5 Put cable cores insert into the corresponding slots and compress the crystal head by professional tool then screw down screw cap slight Refer to Figure 4 4 2 6 Put crystal head insert into the corresponding inner slots of inverter 7 Faste...

Page 18: ...nge white orange green white blue blue white green brown white brown RS485 waterproof assembly RESERVED RESERVED RESERVED 4 5 WiFi Communication Connection Install the antenna to inverter Refer to Figure 4 5 1 Figure 4 5 1 4 6 USB Communication Connection The USB communication is used for firmware update only Please follow below Figure 4 6 1 to implement USB connection ...

Page 19: ...rmal Green Normal Constant on Checking Blink 0 5s on 0 5soff Fault Red Fault Constant on Sale Green Generate to grid Constant on Buy Yellow Consumption from grid Constant on Charge Green Battery Charging Constant on Discharge Green Battery Discharging Constant on Battery Low Red Battery Low Bad Disconnect Blink 0 5s on 0 5soff 6 Error Messages An error message will be displayed on the Monitor if a...

Page 20: ...nt Relay Check Failure Relay self checking failure DC Injection High Overhigh DC injection EEPROM R W Failure Memory chip failure SCI Failure Internal communication failure DC Bus High Overhigh BUS voltage Ref 2 5V Failure 2 5V reference voltage failure AC HCT Failure Output current sensor failure GFCI Failure Detection circuit of ground leakage current failure Vac Failure Grid voltage no longer w...

Page 21: ... included Li Ion Battery voltage sense integrated Current shunt integrated AC Output Data Norminal AC power W 4600 3600 Max AC power W 4600 3600 Peak power Back up W 1 5x Pnom 10sec 1 5x Pnom 10sec Max AC current A 20 16 Norminal AC output 50 60Hz 230Vac AC output range 45 55Hz 55 65Hz 180 270Vac AC output Back up 230Vac 2 50Hz 0 2 THDv 3 linear load THDi 1 5 Power factor 0 9 leading 0 9 lagging G...

Page 22: ...EN61000 6 4 EN61000 3 11 EN61000 3 12 General Data Dimensions WxHxD 516 440 184mm Weight kg 30 28 Mounting Wall bracket Ambient temperature range 20 60 C 45 C derating Relative humidity 0 95 Max operating altitude 2000m Protection degree IP65 Topology Transformerless Standby losses W 8 Cooling Nature convection Noise emision dB 25 Display LED light APP Communication USB2 0 RS485 WIFI CAN Standard ...

Page 23: ...dWe Australia 74 Tarana Avenue Glenroy VIC 3046 Australia T 61 3 9972 9938 australia goodwe com cn www goodwe de GoodWe UK 93 Caversham Place Sutton Coldfield B73 6HW uk goodwe com cn www goodwe com cn GoodWe China No 189 Kunlunshan Rd SND Suzhou 215163 China T 86 512 6239 6771 F 86 512 6239 7972 sales goodwe com cn www goodwe com cn ...