Troubleshooting Repair Guide 0918

4

MACHINE REACTS TO VOLTAGE WHEN TURNED ON BUT 

DOES NOT REACT FUNCTIONALLY:

1.  

The machine receives voltage when turned ON, but nothing functions.  

(LED are alight)
1a.   Measure the voltage of the mains, it must be sufficient to run the machine. 

Low voltage though an overlong extension cord or insufficient mains voltage 

will cause the PCB to go into tilt with continued blinking and strange readouts 

on the temperature display. Same or worse with over-voltage.

1b.   The PCB could be faulty. Exchange the PCB and see if the new one fixes  

the problem.

1c.   If the machine uses a transformer to create a neutral and to deliver single 

phase voltage (230V~) to the PCB and pumps, check the transformer and 

substitute if faulty.

MACHINE BUILDS UP NO TEMPERATURE AND/OR PRESSURE:

1.

  The pressure gauge MAP0027 shows no pressure.

1a.   Make sure that the boiler ON switch is enabled and the green boiler LED is 

blinking or steady ON (see picture 4) and the temperature display shows a 

temperature almost equivalent to what is declared in the instruction manual. 

Enable steam output on the hose and check if steam exits and if yes, then 

exchange the faulty pressure gauge. Otherwise see below.

2b.   Inspect the boiler safety thermostat, it may have been triggered. Try a reset or 

exchange. (see picture 5)

ATTENTION:

 The safety 

thermostat, MAP0206, sets 

off at around 210°C (410°F), 

cutting the power supply 

off. Causes can be boiler 

pump and/or level sensor 

failure or a failure of both 

pressure-stats! Identify the 

cause and exchange the 

faulty parts and set the new 

pressure-stats to the correct 

setting (see table 1 ).

Pic. 4

Summary of Contents for GVC-18000

Page 1: ...Read before operating GVC 18000 GVC 36000 GVC 72000 Troubleshooting Repair Guide 3Phase Machines...

Page 2: ...ble Before attempting to repair a machine gather as much information from the customer as possible Always ask for a clear and detailed description of what the machine does or does not do Many problems...

Page 3: ...faulty 2b Exchange the cable if no voltage reaches the internal mains connector 2c Fasten all loose cables connections 3 Inspect the front panel mains switch making sure that voltage passes when it is...

Page 4: ...ansformer and substitute if faulty MACHINE BUILDS UP NO TEMPERATURE AND OR PRESSURE 1 The pressure gauge MAP0027 shows no pressure 1a Make sure that the boiler ON switch is enabled and the green boile...

Page 5: ...or the protective Teflon sheath will be damaged causing a short circuit and signal failure See chapter 9 for boiler pump Pic 6 Pic 7 Pic 8 1d If pressure is shown but no temperature inspect the specia...

Page 6: ...1f The big contactor relay that connects and disconnects the heating elements through the signal from the working pressure stat could be faulty or have a loose wire Inspect repair or exchange see pic...

Page 7: ...epair or exchange faulty parts 4 Check the hose try with another identical hose for faulty electric connections faulty switches or limestone blockage and repair or exchange faulty parts MACHINE GOES O...

Page 8: ...INE LEAKS STEAM OR WATER 1 With the machine open for inspection turn on and power up When the boiler pump is running inspect the complete assembly closely to find an eventual leakage Tighten loose fit...

Page 9: ...this valve there is also a non return valve This valve can remain blocked so that the pump cannot get water into the boiler Check with a separate pump to see if water goes through and that air bleeds...

Page 10: ...otherwise it is faulty or wiring is ATTENTION In case of a faulty wet steam detergent PCB always first inspect the small pumps to exclude a short circuited pump coil before replacing the small PCB oth...

Page 11: ...ged and heavy use so that the vacuum cannot be turned OFF on the grip but must be turned OFF on the vacuum head 1a Exchange the PCB 2 The vacuum has only low or no suction power 2a Clean or exchange t...

Page 12: ...5 GOODWAY TECHNOLOGIES CORPORATION 420 West Avenue Stamford CT 06902 USA Tel 203 359 4708 Toll Free Tel 800 243 7932 Fax 203 359 9601 Toll Free Fax 800 359 9625 Email goodway goodway com Visit www goo...

Reviews: